Thyracont VSP63D Operating Instructions Manual

Thyracont VSP63D Operating Instructions Manual

Vacuum transducer
Hide thumbs Also See for VSP63D:
Table of Contents

Advertisement

Available languages

Available languages

V a c u u m
I n s t r u m e n t s
VSP63D, VSP64D, VCP63D, VCP64D
VSP63DL, VSP64DL, VCP63DL, VCP64DL
Vakuum Transmitter
Vacuum Transducer
Betriebsanleitung
Operating Instructions

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VSP63D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thyracont VSP63D

  • Page 1 V a c u u m I n s t r u m e n t s VSP63D, VSP64D, VCP63D, VCP64D VSP63DL, VSP64DL, VCP63DL, VCP64DL Vakuum Transmitter Vacuum Transducer Betriebsanleitung Operating Instructions...
  • Page 3: Table Of Contents

    3.3 Elektrischer Anschluss ......3.3.1 Anschluss an Thyracont Anzeigegeräte ... .
  • Page 4: Hinweise Für Ihre Sicherheit

    1 Hinweise für Ihre Sicherheit Lesen und befolgen Sie alle Punkte dieser Anleitung Informieren Sie sich über Gefahren, die vom Gerät ausgehen und Gefahren, die von Ihrer Anlage ausgehen Beachten Sie die Sicherheits- und Unfall-Verhütungsvorschriften Prüfen Sie regelmäßig die Einhaltung aller Schutzmaßnahmen Installieren Sie das VSP/VCP unter Einhaltung der entsprechenden Umgebungsbe- dingungen;...
  • Page 5: Vakuum Transmitter Vsp/Vcp

    2 Vakuum Transmitter VSP/VCP 2.1 Zur Orientierung Diese Betriebsanleitung ist gültig für Produkte mit den Artikelnummern VSP63D, VSP64D, VCP63D, VCP64D, VSP63DL, VSP64DL, VCP63DL, VCP64DL. Sie finden die Artikelnummern auf dem Typenschild. Technische Änderungen oh- ne vorherige Anzeige sind vorbehalten. 2.2 Lieferumfang Zum Lieferumfang gehören:...
  • Page 6: Produktbeschreibung

    - 1000 mbar. Der Transmittertyp VCP mit Pt/Rh Fi- lament ist für den Einsatz in vielen Korrosivgas-Anwendungen geeignet und misst Absolutdruck im Bereich 5,0x10 - 1000 mbar. Das Gerät kann an ein Thyracont Anzeigegerät angeschlossen oder gemäß Anschlussbelegung mit einer kundenei- genen Spannungsversorgung betrieben werden.
  • Page 7: Installation

    3 Installation 3.1 Hinweise zur Installation Keine eigenmächtigen Umbauten oder Veränderungen am Gerät vornehmen! Aufstellungsort: Innenräume Für nicht vollklimatisierte Betriebsräume gilt: Temperatur: +5 C ... +60 C Rel. Luftfeuchte: max. 80% bis 30 C, max. 50% bei 40 C, nicht betauend Luftdruck: 860 - 1060 hPa (mbar) 3.2 Vakuumanschluss Schmutz und Beschädigungen, insbesondere am Flansch, beein-...
  • Page 8: Elektrischer Anschluss

    Druck nicht mehr standhalten. Dies kann zu Gesundheitsschäden durch ausströmende Prozessmedien führen! 3.3 Elektrischer Anschluss 3.3.1 Anschluss an Thyracont Anzeigegeräte Wird der Transmitter an einem Thyracont Anzeigegerät betrieben, ist ein geeigne- tes Messkabel zu verwenden (siehe Zubehör). Anschluss des Transmitters niemals mit Spannung führendem Ka- bel herstellen! Stecker am Transmitter einstecken und mit Schrauben sichern.
  • Page 9: Kundeneigene Spannungsversorgung

    3.3.2 Kundeneigene Spannungsversorgung Der Transmitter kann auch mit anderen Anzeigegeräten oder kundeneigener Span- nungsversorgung betrieben werden. Die elektrische Verbindung ist unter Verwendung geeigneter Kabel EMV-gerecht gemäß untenstehender Pinbelegung herzustellen: Stecker Sub-D, 15polig, männlich Pin1: Identifikation: 15 k Pin2: Signal Output 0-10 VDC Pin3: AGND Pin4:...
  • Page 10: Betrieb

    4 Betrieb 4.1 Allgemeines Messprinzip Vakuum Transmitter des Typs VSP und VCP besitzen einen Piranisensor, der die Wärmeleitfähigkeit von Gasen zur Vakuummessung nutzt. Beim Wärmeleitungssensor wird ein Wendel-Filament in einer Wheatstone Brü- ckenschaltung auf eine konstante Temperatur aufgeheizt. Die notwendige Brücken- spannung ist ein Maß...
  • Page 11: Bedienung Des Vsp/Vcp

    4.2 Bedienung des VSP/VCP Die Status-LED des VSP/VCP signalisiert folgende Betriebszustände: Die Schaltpunkt LEDs leuchten, sobald das zugehörige Relais angezogen ist. Die Modelle VSP63DL, VSP64DL, VCP63DL und VCP64DL verfügen zudem über eine gelb hinterleuchtete LCD Anzeige. Diese zeigt den aktuell gemessenen Ist- Druck.
  • Page 12: Nachjustieren

    Anzeigeeinheit und Display-Orientierung können per Softwarekommando geän- dert werden, siehe hierzu Abschnitt 5.5. 4.3 Nachjustieren Das Gerät ist ab Werk bei Versorgungsspannung 24 V stehend, d.h. mit dem Flansch nach unten, abgeglichen. Andere Einbaulagen, Einsatz unter anderen klimatischen Bedingungen, extreme Temperaturschwankungen, Alterung oder Verschmutzung können ein Nachjustie- ren des Pirani-Sensors erforderlich machen.
  • Page 13 Zum Justieren den Gummistopfen über dem Taster »Adj« entfernen (1), dann mit einem dünnen Schraubendreher oder ähnlichem Hilfsmittel mehrmals kurz auf den Taster drücken (2), bis die Status-LED schnell orange zu blinken beginnt. Nach 3 s ohne weiteren Tastendruck signalisiert langsames Blinken, dass der Transmitter nun nachjustiert werden kann.
  • Page 14: Ausheizen

    Nachjustieren per Software-Kommando Siehe Abschnitt 5.7. 4.4 Ausheizen Soll die Vakuumkammer mit angeflanschtem VSP/VCP ausgeheizt werden, so darf die Temperatur am Sensorflansch 150 C keinesfalls überschreiten. Die Spannungsversorgung des Transmitters muss während des Ausheizens der Kammer ausgeschaltet sein. Anderenfalls kann es zu Schäden an der Elektronik kommen! VSP/VCP-RS485-200116...
  • Page 15: Kommunikation

    Wert zwischen 1 und 16 einzustellen (2). Danach den Gummistopfen wieder ein- setzen. Bei der Kommunikation werden die Telegramme gemäß Thyracont Protokoll Versi- on V2 als ASCII-Code übertragen. Ausführliche Informationen hierzu finden Sie in der gesonderten Beschreibung »Thyracont Communication Protocol«.
  • Page 16: Parameterübersicht

    5.2 Parameterübersicht Command Code Type of Device Product Name Serial Number Device Serial Number Head (Sensor) Version Device Version Firmware Version Bootloader Baud Rate Response Delay Device Restart Measurement Range Measurement Value Display Unit Display Orientation Relay 1 Relay 2 Adjust High (Atmosphere Pressure) Adjust Low (Zero Pressure) Gas Correction Factor 1 (Pirani)
  • Page 17: Geräte-Parameter Und Information

    5.3 Geräte-Parameter und Information Type of Device (TD): Abfragen des Gerätetyps, z.B. VSP206 Product Name (PN): Abfragen des Produktnamens (entspricht der Artikelnummer) Serial Number Device (SD): Abfragen der Geräte-Seriennummer Serial Number Head (SH): Abfragen der Seriennummer des Sensorkopfes Version Device (VD): Abfragen der Hardware-Versionsnummer des Geräts Version Firmware (VF): Abfragen der Firmware-Versionsnummer des Geräts...
  • Page 18: Messwertabfrage

    5.4 Messwertabfrage Measurement Range (MR): Abfragen des Messbereichs Measurement Value MV: Abfragen des aktuell gemessenen Druckwertes 5.5 Displayfunktionen Display Unit (DU): Abfragen und Einstellen der für das LCD Display des Transmitters verwendeten Druckeinheit. Wertebereich: mbar (Default), Torr, hPa Display Orientation (DO): Abfragen und Einstellen der Display-Orientierung, die Anzeige kann dadurch um 180 gedreht werden.
  • Page 19 Relay R1, R2: Die Relais können unabhängig voneinander für verschiedene Schaltmodi konfigu- riert werden, der Parameter dient zum Abfragen und Einstellen dieser Schaltmodi. Einstellung T[p1] F[p2]: Hier werden zwei Druckwerte T[p1] (true) und F[p2] (false) übertragen. Fall T[p1] < F[p2]: Das Relais zieht bei Unterschreiten des Druckwerts T[p1] an und fällt bei Überschreiten des Druckwerts F[p2] ab.
  • Page 20: Nachjustieren

    Einstellung E: Relais zieht an bei Gerätefehler. Einstellung !E: Relais fällt ab bei Gerätefehler. Einstellung U: Relais zieht an bei Messbereichsunterschreitung. Einstellung !U: Relais fällt ab Messbereichsunterschreitung. Einstellung T0: Relais per Software-Kommando ausschalten (off). Einstellung T1: Relais per Software-Kommando einschalten (on). Die Kontroll-LEDs auf der Steckerseite des Transmitters leuchten, sobald das zugehörige Relais angezogen ist.
  • Page 21: Sensor Parameter

    5.8 Sensor Parameter Gasart-Korrekturfaktoren - Gas Correction Factor (C1) Das Mess-Signal des VSP/VCP ist gasartabhängig. Das Gerät ist auf N bzw. trockene Luft abgeglichen. Für andere Gase kann die Druckausgabe unterhalb 0,1 mbar korrigiert werden, indem ein entsprechender Korrekturfaktor gesetzt wird. Die Messwerte des Sensors werden dann bereits im Gerät mit dem Korrekturfak- tor multipliziert, so dass am analogen und digitalen Ausgang des Transmitters ein korrigiertes Mess-Signal zur Verfügung steht.
  • Page 22: Vacugraph Software

    5.9 VacuGraph Software Die Software VacuGraph wurde speziell für den Einsatz mit Thyracont Messgerä- ten entwickelt und läuft auf den Betriebssystemen Windows, Linux, MacOS und Android. Sie ermöglicht neben dem Plotten und Speichern von Messdaten auch das be- queme Konfigurieren aller Geräteparameter.
  • Page 23: Wartung Und Service

    1,0 V / »UR« via RS485 unterschritten Messgrenze) Mess-Signal < 0,5 V / Elektronik oder Sensor Gerät einschicken oder »ERROR1« via RS485 / defekt Sensor ersetzen Status LED dauer-rot Access Code »7« via Fehlermeldung / Warnung siehe gesonderte RS485 Beschreibung Thyracont Communication Protocol VSP/VCP-RS485-200116...
  • Page 24 VSP/VCP-RS485-200116...
  • Page 25: Technische Daten

    7 Technische Daten Messprinzip Wärmeleitfähigkeit Pirani, gasartabhängig Messbereich VSP: 1000 - 1,0x10 mbar (750 - 1,0x10 Torr) VCP: 1000 - 5,0x10 mbar (750 - 5,0x10 Torr) Max. Überlast 10 bar abs. Genauigkeit VSP: 1000 ... 20 mbar: ca. 30% v. Messwert 20 ...
  • Page 26 Leistungsaufnahme max. 2,5 W, zusätzlich 0,8 W für Relais und LCD Ausgangssignal 0 - 10 VDC, min. 10 k , Messbereich VSP: 1,5 - 8,5 VDC, logarithmisch Messbereich VCP: 2,2 - 8,5 VDC, logarithmisch Serielle Schnittstelle RS485: 9,6 ... 115 kBd, 8 databit, 1 stopbit, no parity Schaltausgänge 2x Relais, potentialfrei...
  • Page 27: Konformitätserklärung

    8 Konformitätserklärung VSP/VCP-RS485-200116...
  • Page 28 VSP/VCP-RS485-200116...
  • Page 29 3.3 Electrical Connection ......3.3.1 Operation with Thyracont Display Unit ... . .
  • Page 30: Safety Instructions

    1 Safety Instructions Read and follow the instructions of this manual Inform yourself regarding hazards, which can be caused by the product or arise in your system Comply with all safety instructions and regulations for accident prevention Check regularly that all safety requirements are being complied with Take account of the ambient conditions when installing your VSP/VCP;...
  • Page 31: Vacuum Transducer Vsp/Vcp

    2.1 For Orientation These operating instructions describe installation and operation of products with article numbers VSP63D, VSP64D, VCP63D, VCP64D, VSP63DL, VSP64DL, VCP63DL, VCP64DL. The article number can be found on the product’s type label. Technical modificati- ons are reserved without prior notification.
  • Page 32: Product Description

    5.0x10 - 1000 mbar. The transdu- cer can be connected to Thyracont display and control units or to customer related power supply and evaluation units in compliance with pin assignment. The analog output signal 1.5 V - 8.5 V of VSP and 2.2 V - 8.5 V of VCP, respectively, has a logarithmic dependence on pressure over the whole range.
  • Page 33: Installation

    3 Installation 3.1 Notes for Installation Unauthorized modifications or conversions of the instrument are not allowed! Installation location: Indoor For not fully air conditioned open buildings and operation rooms: Temperature: +5 C ... +60 C Rel. humidity: max. 80% up to 30 C, max. 50% at 40 C, non-condensing Ambient pressure: 860 - 1060 hPa (mbar) 3.2 Vacuum Connection Dirt and damage, especially at the vacuum flange, have an adver-...
  • Page 34: Electrical Connection

    3.3 Electrical Connection 3.3.1 Operation with Thyracont Display Unit For operation of the transducer with a Thyracont display and control unit a suitable measurement cable must be used (see accessories). Do not connect or disconnect the transducer when the cable is on circuit! Connect the cables plug to the transducer and secure it with the screw.
  • Page 35: Operation With Other Supply And Evaluation Units

    3.3.2 Operation with other Supply and Evaluation Units The transducer can be operated with other customer related display units or volta- ge supplies. The electrical connection is to be made by means of suitable cables considering EMI demands and according to the pin description shown below: Socket Sub-D, 15-pole, male Pin1:...
  • Page 36: Operation

    4 Operation 4.1 General Measurement Principle VSP and VCP vacuum transducers are equipped with an internal Pirani sensor. The Pirani principle uses the heat conduction of gases for measuring vacuum. A sensor filament in a Wheatstone circuit is heated to a constant temperature, so the bridge voltage is a measure for total gas pressure.
  • Page 37: Operation Of The Vsp/Vcp

    4.2 Operation of the VSP/VCP The status LED of the VSP/VCP signalizes the following operational states: The switchpoint LEDs are on when the related relay is activated. In addition models VSP63DL, VSP64DL, VCP63DL and VCP64DL have an LCD with yellow backlight that displays the measured actual pressure. In case of an operation error or malfunction the display is illuminated by a red back- ground color.
  • Page 38: Readjustment

    Display unit and orientation can be changed by software command, see section 5.5. 4.3 Readjustment The transducer is adjusted ex works with 24 V voltage supply in upright position, flange to the bottom. Other orientation, operation under different climatic conditi- ons, extreme temperature changes, ageing or contamination can result in the need for readjustment of the Pirani sensor.
  • Page 39 For adjustment first remove the rubber cap above the »Adj« button (1), then press the pushbutton several times by means of a screwdriver or other suitable tool (2) until the status LED starts quickly flashing orange. After further 3 s a slowly fla- shing status LED signalizes that the transducer now can be readjusted by pushing the button once again.
  • Page 40: Bake-Out

    Readjustment via Software Command See section 5.7. 4.4 Bake-Out When a bake-out of the vacuum chamber is performed with the VSP/VCP being mounted to the chamber, the temperature at the sensor flange must not exceed 150 C. The transducer’s voltage supply must be switched-off while the chamber is heated.
  • Page 41: Communication

    (2). Afterwards insert the rubber cap again. Communication telegrams are transmitted as ASCII text according to the Thyra- cont protocol version V2. Detailed information is provided in the separate descrip- tion »Thyracont Communication Protocol«. Download link: www.thyracont-vacuum.com/en/support/downloadcenter/ Interface Parameter: 9.6 / 14.4 / 19.2 / 38.4 / 57.6 / 115.2 kBd, 8 databits, 1 stopbit, no parity...
  • Page 42: Survey Of Commands

    5.2 Survey of Commands Command Code Type of Device Product Name Serial Number Device Serial Number Head (Sensor) Version Device Version Firmware Version Bootloader Baud Rate Response Delay Device Restart Measurement Range Measurement Value Display Unit Display Orientation Relay 1 Relay 2 Adjust High (Atmosphere Pressure) Adjust Low (Zero Pressure)
  • Page 43: Device Parameters And Information

    5.3 Device Parameters and Information Type of Device (TD): Query of device type, e.g. VSP206 Product Name (PN): Query of product name (article number) Serial Number Device (SD): Query of device serial number Serial Number Head (SH): Query of sensor head serial number Version Device (VD): Query of the device’s hardware version Version Firmware (VF):...
  • Page 44: Measurement Query

    5.4 Measurement Query Measurement Range (MR): Query measurement range of the gauge Measurement Value MV: Query current pressure measurement 5.5 Display Functions Display Unit (DU): Query and set the pressure unit used for the LCD display of the transducer. Value range: mbar (default), Torr, hPa Display Orientation (DO): Query and set display orientation, i.e.
  • Page 45 Setting T[p1] F[p2]: In this case 2 pressure thresholds T[p1] (true) and F[p2] (false) are transmitted. T[p1] < F[p2]: The relay closes when actual pressure falls below threshold T[p1] and opens again as soon as actual pressure exceeds threshold F[p2]. T[p1] >...
  • Page 46: Readjustment

    Setting E: Relay closes in case of a device error. Setting !E: Relay opens in case of a device error. Setting U: Relay closes in case of pressure underrange. Setting !U: Relay opens in case of pressure underrange. Setting T0: Open relay by software command (off).
  • Page 47: Sensor Parameters

    5.8 Sensor Parameters Gas Correction Factor (C1) The measurement signal of the VSP/VCP depends on type and composition of the gas being measured. The unit is adjusted for N and dry air. For other gases the pressure display can be corrected below 0.1 mbar by setting a correction factor. The measurement results of the sensor are then multiplied with the correction fac- tor by the unit’s microcontroller, thereby providing a corrected pressure reading as analog and digital output.
  • Page 48: Vacugraph Software

    5.9 VacuGraph Software VacuGraph software has been especially developed for use with Thyracont gauges and is compatible with operating systems Windows, Linux, MacOS and Android. VacuGraph features plotting and saving of measurement data as well as comfor- table configuration of all device parameters.
  • Page 49: Maintenance And Service

    < 0.5 V / defective electronics or send unit for repair or »ERROR1« via RS485 / sensor replace sensor status LED cont. red access code »7« via error message / warning see separate RS485 documentation Thyracont Communication Protocol VSP/VCP-RS485-200116...
  • Page 50 VSP/VCP-RS485-200116...
  • Page 51: Technical Data

    7 Technical Data Measurement principle heat conduction Pirani, depending on gas type Measuring range VSP: 1000 - 1.0x10 mbar (750 - 1.0x10 Torr) VCP: 1000 - 5.0x10 mbar (750 - 5.0x10 Torr) Max. overload 10 bar abs. Accuracy VSP: 1000 ... 20 mbar: approx. 30% f. reading 20 ...
  • Page 52 Power consumption max. 2.5 W 0.8 W for relays and LCD Output signal 0 - 10 VDC, min. 10 k , measuring range VSP: 1.5 - 8.5 VDC, logarithmic measuring range VCP: 2.2 - 8.5 VDC, logarithmic Serial interface RS485: 9.6 ... 115 kBd, 8 databit, 1 stopbit, no parity Switchpoints 2x relay, potential free...
  • Page 53: Declaration Of Conformity

    8 Declaration of Conformity VSP/VCP-RS485-200116...
  • Page 54 VSP/VCP-RS485-200116...
  • Page 55 VSP/VCP-RS485-200116...
  • Page 56 VSP/VCP-RS485-200116...

This manual is also suitable for:

Vsp64dVcp63dVcp64dVsp63dlVsp64dlVcp63dl ... Show all