Omega HHP460 User Manual

Omega HHP460 User Manual

Smart manometer with altimeter and air speed tester
Table of Contents

Advertisement

Quick Links

User Manual
www.omega.com
info@omega.com
1-800-826-6342
HHP460
Smart Manometer
With Altimeter and Air Speed Tester
© Omega 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HHP460 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Omega HHP460

  • Page 1 User Manual www.omega.com info@omega.com 1-800-826-6342 HHP460 Smart Manometer With Altimeter and Air Speed Tester © Omega 2021...
  • Page 2: Table Of Contents

    HHP400 Suite and USB Drivers required ............37 Tips for using HHP400 Suite ..................38 Connection status......................41 Configuration button ......................43 User Calibration button ....................47 Data Log button .........................49 User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 2 of 72...
  • Page 3 Weight ............................69 Enclosure ..........................69 Maintenance and cleaning ........................70 Cleaning ...........................70 Prepare the Smart Manometer for storage ............70 Register your product ...........................71 Find downloads and documents ................71 User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 3 of 72...
  • Page 4: General Information

    Omega or its affiliates. It is not possible for Omega to identify all foreseeable uses or misuses, therefore all persons involved in commissioning, using, or maintaining this product must satisfy their self that each intended application is acceptable.
  • Page 5: Glossary

    • Data from the internal and external pressure p1 . P 2 sensors display in two lines on the Smart Manometer at the same time. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 5 of 72...
  • Page 6 • The asterisk displays when you enable the Sea Level Correction offset or enable the Altitude Correction offset. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 6 of 72...
  • Page 7: General Warnings And Cautions

    Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. Indicates information essential for proper product installation, operation or maintenance. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 7 of 72...
  • Page 8: Sample Label For General Purpose Smart Manometers

    Do not power the Smart Manometer with a combination of ▪ new and old batteries. ▪ Do not power the Smart Manometer with a combination of batteries from different manufacturers. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 8 of 72...
  • Page 9: Do Not Exceed Pressure Limits

    Pressure Limits listed in the Specifications ▪ section of this manual. Failure to operate within the specified pressure limit could ▪ result in minor or moderate injury. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 9 of 72...
  • Page 10: Sensors

    Note: See Overrange limit in the section called Specifications concerning overrange pressure limits. If over pressure damage occurs, you must return the Smart Manometer to the factory for sensor replacement. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 10 of 72...
  • Page 11: Omega Tethered Sensors

    Align the red dot on the Smart Manometer with the red dot on ▪ the Tether cable and push in. Align the red dot on the Omega Tethered Sensors with the red ▪ dot on the Tether cable and push in.
  • Page 12 • This refers to User Defined Offset (Zero). You u5Er 0 can set an absolute reference point other than zero. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 12 of 72...
  • Page 13: How To Zero Dn, Di, Or Ci Sensors

    Factory service may be required. 5. You can turn off the Zero function in HHP400 Suite deselecting Allow zero adjust (Ø) in the Display Functions list. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 13 of 72...
  • Page 14: Altitude And Indicated Air Speed

    IAS MPH (mi/h). 2. Press Units key when IAS MPH is on-screen to switch from MPH to KNOTS to KM/H and back to MPH. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 14 of 72...
  • Page 15: Altitude Correction In Feet (Meters)

    2. Information: 0 Clears refers to the Zero key. Pressing it clears any numbers you entered after pressing the Up or Down arrow keys. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 15 of 72...
  • Page 16: Sea Level Correction In Meters

    Sea Level Correction data by using the arrow keys. 4. While in the edit screen, the HHP400 displays the following message: SEA LEVEL CORRECTION √ SAVES X CANCELS 0 CLEARS User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 16 of 72...
  • Page 17 (*) appears on the Home, the ALT FEET, and IAS MPH screens to indicate that either an Altitude Offset or Sea Level Offset has been set or both of Offsets have been set. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 17 of 72...
  • Page 18: Switch To Omega Tethered Sensor

    SEA LEVEL CORRECTION IN METERS TAP ✓ TO CHANGE 2. ALTITUDE CORRECTION IN FEET TAP ✓ TO CHANGE 3. IAS MPH 4. ALT FEET (Altitude Display) or BEYOND MAX. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 18 of 72...
  • Page 19: Smart Manometer

    ▪ ▪ Energizer EN91 Panasonic LR6XWA ▪ Rayovac 815 ▪ ▪ Varta 4906 Note: The Smart Manometer is powered by four 1.5 volt AA size batteries. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 19 of 72...
  • Page 20 Refer to battery manufacturers’ instructions Visit the website of the battery manufacturer to learn more about the care, storage, shipping, use, disposal, and recycling of your batteries. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 20 of 72...
  • Page 21: The Display

    FS. Note: When you press the Information key, the bar graph displays the remaining state of the charge for the batteries. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 21 of 72...
  • Page 22 2. SEA LEVEL CORRECTION IN METERS TAP ✓ TO CHANGE 3. ALTITUDE CORRECTION IN FEET TAP ✓ TO CHANGE 4. IAS MPH 5. ALT FEET (Altitude Display) or BEYOND MAX. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 22 of 72...
  • Page 23: Keypad: Description Of The Keys

    Power • Turns the Smart Manometer on or off. Information • Displays information about the Smart Manometer, internal sensor, attached Omega Tethered Sensors and the firmware. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 23 of 72...
  • Page 24 USB POWER. SEA LEVEL CORRECTION: On or Off ALTITUDE CORRECTION: On or Off 4. If you have an Omega Tethered Sensors attached to the Smart Manometer. -- P1 -- -- P2 -- Note: the bottom row indicates sensor (or measurement type): compound, absolute, or differential.
  • Page 25: The Backlight

    Pressure has fallen below the stated accuracy of the Smart ▪ Manometer. Note: The red backlight overrides the white backlight. Overrange condition During an error or overrange condition, the red backlight overrides the white backlight. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 25 of 72...
  • Page 26 However, once the error or overrange condition is corrected, the white backlight is restored to its previous state (if the backlight Auto Off timeout did not expire). User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 26 of 72...
  • Page 27: Measurement Units

    Standard Measurement Units (non-custom) CMW4C KG/M2 INW20C CMW60F INW4C MW2OC INW60F MW4C FTW2OC MW60F INHG0C FTW4C FTW60F MGH0C MBAR MMW20C CMGH0C MMHG0C OZ/IN2 MMW4C MMW60F TORR LB/FT2 CMW2OC KG/CM2 User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 27 of 72...
  • Page 28: Damping

    Exponential damping displays approximately 70 % of a step ▪ change in pressure at the next display update. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 28 of 72...
  • Page 29: Data Logging

    Stopping a data log To stop the Data Log at any point or at any time, press and hold Stop key until appears. -- Stopping -- User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 29 of 72...
  • Page 30: Leak Test

    “0” key to reset all numbers to zeros and enter a valid number of minutes from 0.1 - 1440. Start the Leak Test Starting from the Home screen: User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 30 of 72...
  • Page 31 Starting. In a Leak Test press and release the Start key (the on-screen message refers to this action as TAP). User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 31 of 72...
  • Page 32 Exit the test during the count down to zero Press the Cancel key or the Accept key to exit the test. 2. Press the Home key to return to the Home screen. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 32 of 72...
  • Page 33: Relief Valve Test

    Press the Zero key and appears and new values HOLD.OFF continue to display. Forward 5. Press the key to see value. MAX TEST P User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 33 of 72...
  • Page 34: Display Information From Two Sensors

    (internal measurement units). ▪ Press the Down arrow to reverse the sequence. Press the Home key at any point to return to the Home screen. ▪ User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 34 of 72...
  • Page 35: Auto Off (Automatic Shut Off)

    The Auto Off timeout is suspended during Data Logging ▪ Leak Test sessions to prevent accidental loss of data. Auto Shut-Off automatically restarts after Data Logging or ▪ Leak Test sessions stop. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 35 of 72...
  • Page 36: What Does The Zero (Ø) Key Do

    Holding the Zero key The key must be held to perform the Zero or Tare mode. The displayed value(s) dashes out during the zero or tare process. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 36 of 72...
  • Page 37: Hhp400 Suite Application

    Instructions. on the Downloads page on www.Omega.com. 2. The instructions have links that you can click to download the required USB Driver. 3. Follow the on-screen instructions. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 37 of 72...
  • Page 38: Tips For Using Hhp400 Suite

    Close HHP400 Suite first, disconnect the USB, and turn off ▪ your Smart Manometer. As long as remains visible, Auto Off is ▪ USB ACTIVE suspended. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 38 of 72...
  • Page 39 You may click the Write button to save the changes you made. Figure 1: Yellow dot on an active tab. See the red circle in the figure below. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 39 of 72...
  • Page 40 US - Eastern -5:00 US - Pacific-8:00 US - Central -6:00 US - Alaska -9:00 US - Mountain -7:00 US - Hawaii -10:00 For example: 15:05:45 UTC (hours:minutes:seconds). ▪ User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 40 of 72...
  • Page 41: Connection Status

    Attached devices The HHP400 Suite application displays the figures of the Smart Manometer and tethered sensor. Descriptions appear alongside both of them. See the figure below. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 41 of 72...
  • Page 42 The HHP400 Suite application displays no figure of devices on the right side. See the figure below. No tethered sensor attached Notice the figure of the Smart Manometer and description. See the figure below. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 42 of 72...
  • Page 43: Configuration Button

    Each device can have its password turned on or turned off ▪ independently from any other tethered sensor. ▪ HHP400 Suite retrieves the passwords stored on the devices. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 43 of 72...
  • Page 44 When you call Omega to generate a recovery password, you may select a date that is convenient for you. If you do not specify a date, the request date is used. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 44 of 72...
  • Page 45 ▪ Average. ▪ ▪ Rate of Change. Relief Valve Test. ▪ Time & Temp. ▪ ▪ Data Log. ▪ Allow zero adjust (Ø). Leak Test. ▪ User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 45 of 72...
  • Page 46 Exponential ▪ damping displays approximately 70 % of a step change in pressure at the next display update. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 46 of 72...
  • Page 47: User Calibration Button

    4. Enter the reference value. 5. Save the point. 6. Repeat steps 2-5 until you are done. (You have to change at least one point.) Click the Apply button. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 47 of 72...
  • Page 48 Calibration Procedure. It is intended to correct the curve fit if the actual sensor characteristics change slightly over time. For sensors up to 200 psi, Omega recommends a ± 0.0015 % of reading deadweight tester. For sensors 200 psi and above, a ±...
  • Page 49: Data Log Button

    The button displays a yellow alert icon to indicate you have changed a setting and you have not yet saved the setting to the Smart Manometer. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 49 of 72...
  • Page 50 The Temperature ▪ The Omega Tethered Sensors displays when it is attached (pressure or temperature). Temperature displays only when the Omega Tethered Sensors ▪ RTD is attached. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 50 of 72...
  • Page 51: Tsv File Format

    TSV file. 4. Select the file and drag-and-drop it in the middle of the blank spreadsheet. 5. Save it as an Excel file. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 51 of 72...
  • Page 52 Double click a log to open it in the Preview tab. ▪ Or, you may select a log from the list and click the Preview ▪ to view it. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 54 of 72...
  • Page 53 The Preview tab contains seven areas of information: Data Log Information list. 2. Sensor Information list. 3. Notes. 4. Legend. 5. Samples table. 6. Navigation bar. Save button. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 55 of 72...
  • Page 54 3. Notes ▪ Any information that displays here comes from the text you enter in the Notes box in the Data Log Pro Setup tab. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 56 of 72...
  • Page 55 Click the Save button on the right side and the Save As appears. You can save the file in two file formats: PDF. ▪ TSV. ▪ User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 57 of 72...
  • Page 56 Notes you enter in this edit box appear in the Preview tab, the TSV file, and the PDF file. This field is limited to 64 characters. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 58 of 72...
  • Page 57 Manometer and overwrites the parameters stored on the Smart Manometer. Note: If a sensor has a password, then clicking this button requires you to enter a password. This password was created in Configuration tab. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 59 of 72...
  • Page 58: Application Button

    “There is no connection to the update server. This is usually caused by the PC not having internet connectivity or the server may be temporarily unavailable. ” User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 60 of 72...
  • Page 59: Update Button

    “There is no connection to the update server. This is usually caused by the PC not having internet connectivity or the server may be temporarily unavailable. ” User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 61 of 72...
  • Page 60: Omega Tethered Sensors: Type And Range

    Omega Tethered Sensors: type and range Omega Tethered Sensors Model number Pressure range Absolute Isolated (AI) HHP460-A 0 psi 15 psi HHP460-B 0 psi 30 psi User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 62 of 72...
  • Page 61 –14.5 psi 1000 psi HHP452-Z-TS –14.5 psi 3000 psi Absolute Isolated (AI) HHP452-Q-TS 0 psi 15 psi HHP452-I-TS 0 psi 30 psi HHP452-R-TS 0 psi 100 psi User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 63 of 72...
  • Page 62 Warm up time: 5 minutes. ▪ ▪ You should zero the sensor at working ambient temperature before using it. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 64 of 72...
  • Page 63: Overrange Limit

    Relative Humidity 95 % non-condensing. ▪ Vibration 1 meter drop test. ▪ Ingress specifications IP52 for the HHP400. ▪ IP54 for the Omega Tethered Sensors. ▪ User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 65 of 72...
  • Page 64: Altitude Specifications

    Note: The barometric pressure value is captured when IAS MPH (KNOTS or KM/H) appears on screen. It determines the maximum indicated air speed. Keypad Sealed membrane 16 domes. ▪ User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 66 of 72...
  • Page 65: Media Compatibility

    1000 psi common mode, P1 (HI) only is 3x range, P2 ▪ (LO) only is 3x range or 150 PSI, whichever is less. Battery Type • 4 AA alkaline batteries of the same battery type. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 67 of 72...
  • Page 66: Emc Compliance

    In the unlikely event of such an occurrence, users should ensure they discharge any static charge they may be carrying by touching a known grounded conductive surface prior to operating the equipment . User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 68 of 72...
  • Page 67: Dimensional Specifications

    ▪ Smart Manometer: 1000 g (35.2 oz. or 2.2 lb.) Omega Tethered Sensors pressure module: 148 g or 0.33 lb. ▪ Enclosure Polycarbonate / ABS alloy. User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 69 of 72...
  • Page 68: Maintenance And Cleaning

    Store the Smart Manometer The recommended storage temperature for the Smart ▪ Manometer is between: –20 °C to 70 °C (–4 °F to 158 °F). User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 70 of 72...
  • Page 69: Register Your Product

    User Manuals and Quick Start Guides Downloads | Applications (software), firmware, updates, installation instructions Certifications | Certifications and approvals SDS (MSDS) | Safety Data Sheets Control Drawings | Intrinsically Safe Drawings User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 71 of 72...
  • Page 70 An RMA number must accompany all incoming packages to insure proper tracking, processing, and repair work. Questions? Contact Omega Call ............(800) 826-6343 Email ..........info@omega.com User Manual HHP460 Smart Manometer with Altimeter & Air Speed Test 72 of 72...

Table of Contents