Replace Batteries; Check Monitor Functions And All Other Instrument Operation - Hitachi ZW 550-6 Operator's Manual

Wheel loader
Table of Contents

Advertisement

Replace Batteries

IMPORTANT: Before adjusting electrical system or
welding on the machine, disconnect the negative
side of the battery, or turn the battery disconnect
switch to OFF position.
Your machine has two 12-volt batteries (1) with negative (-)
ground.
If one battery in a 24-volt system has failed but the other
is still good, replace the failed battery with an operable
battery of the same type. For example, replace a failed
maintenance-free battery with a new maintenance-free
battery.
Different types of batteries may have different rates of
charge. This difference could overload one of the batteries
and cause it to fail.
f
NOTE: When replacing batteries (1), remove bolts (2) (5
used) and remove box (3) surrounding the batteries.
j : 17 mm
m : 53 N·m (5.4 kgf·m, 39 lbf·ft)
Box (3) weight: 25 kg (55 lb)
Check Monitor Functions and All Other
Instrument Operation
--- every 10 hours (daily)
Run the engine at low idle when checking the instruments.
The monitor indicates alarm, caution and confirmation
status in red, orange, and normal operative condition in
blue or green respectively.
Check each gauge or meter if its needle is moved with
the key switch ON. The needle shall be moved to the blue
range when normal and to the red range when abnormal.
Refer to the Group of Operator's Station in Section 1 for
more information.
MAINTENANCE
7-84
3
1
2
115Z7-07-81