Start-Up Instructions - Bonnet Neve SKIVIEW INTEGRAL WL User Instructions

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 37
Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
10. PRESCRIPTIONS AND RESTRICTIONS
KEEPING PHARMACEUTICAL PRODUCTS IN THE DISPLAY CASE IS STRICTLY FORBID-
DEN (FIG.10).
Do not remove protections or panels when it requires the use of tools. IN PARTICULAR,
DO NOT REMOVE THE ELECTRIC CONTROL BOARD COVER.
Ù
DO NO STORE EXPLOSIVE SUBSTANCES, SUCH AS SPRAY CANS CONTAINING FLAM-
MABLE PROPELLANTS, INSIDE THIS EQUIPMENT.
Do not expose the display case to atmospheric agents (fig. 15). DO NOT STEP
on the cabinet bumper rail. DO NOT STEP ON THE TOP OF THE CABINET AND
DO NOT LAY WEIGHTS ON IT.
Do not spill water directly or indirectly on the display case (fig. 14). Do not touch the
equipment with damp or wet hands or feet; do not use it while barefoot (fig. 16).
ANY OTHER USE NOT EXPRESSLY MENTIONED IN THIS BOOKLET MUST BE CONSIDE-
RED AS HAZARDOUS. THE MANUFACTURER ASSUMES NO RESPONSIBILITY FOR ANY
DAMAGE RESULTING FROM IMPROPER, INCORRECT OR UNREASONABLE USE.
The instructions concerning persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge and children playing with
the appliance are not required.
HEAT TRANSFER LIQUIDS:
Only monoethyl glycol and monopropyl glycol liquids with concentrations above 30%
are authorized.
The systems in which these liquids are used must comply with current health regula-
tions and, in particular, be equipped with a system for the prevention of discharge into
drinking water.
The use of a corrosion inhibitor is mandatory.

START-UP INSTRUCTIONS:

We strongly recommend that you thoroughly clean the systems before filling up and
completely drain the system after filling.
To prevent the risk of scaling and deposit of inhibition systems, we recommend you use
demineralized water.
The pH of the solution should never exceed 7.
MAINTENANCE:
We recommend you check the pH and the concentration of the solution used at least
once a year.
SKYVIEW INTEGRAL WL
Epta France S.A. - Allée de l'Industrie - 64700 Hendaye (FR)
T + 33 (0)5 59 51 62 62
F + 33 (0)5 59 51 68 04
40/64
PAGE:
UM000414
N° DOC.

Advertisement

Table of Contents
loading

Table of Contents