Pentair MASTERTEMP 125 Installation And User Manual page 27

Pool and spa heater (euro)
Table of Contents

Advertisement

Section 1. Installation
18 |
USE THE PROVIDED WATERPROOF WIRE NUTS WHEN CONNECTING THE POWER SUPPLY.
A time clock controlling the filter pump should have a low-voltage Fireman's Switch that switches off the heater at
least 15 minutes before shutting off the pump.
1. -
Remove the factory installed jumper from the Fireman's Switch terminals.
- Connect wires between the Fireman's Switch terminals on the heater and the relay. Connect wires from the
controller or timer to the Fireman's Switch. Controller, timer or relay should be sized to handle 24VAC at 0.5
Amp (because it will be completing the 24VAC control board circuit on the heater as shown in Figure 31 (page
23). DO NOT apply line voltage to the Fireman's Switch terminals. Use 18 gauge wire with a minimum 1.2
mm (3/64 in.) thick insulation rated for a temperature rise of at least 105° C.
- Knock-outs are provided to route the wires through the bottom of the control box and past the junction box.
2. To connect a 3-Wire Control:
- Connect wires between the control board terminals on the heater and the
external relays, as shown in Figure 31, on page 23. Use at least 2 relays per
heater, to allow for an "OFF setting" on each heater mode. Select relays
that can handle logic level switching. DO NOT apply line voltage to control
board terminals.
- Move jumper (as show in Figure 25) to enable external control and to disable
the heater membrane pad's "Pool POOL/SPA buttons (the HEATER (ON/
OFF button control panel remains functional).
BK
O
Figure 25.
MASTERTEMP 125 Pool and Spa Heater Installation and User's Guide
BK
O
TRANS
J6
OPERATING CONTROL
MEMBRANE PAD
CONNECTION
ENABLE TOGGLE
DISABLE TOGGLE
TERMINAL BOARD
F
S
I
R
W
I
E
L1
FL
M
T
A
C
H
N
F1
S
L1
L2
GND
24VAC
Y
Y
Y Y
24 VAC
W
W
TRAN S
W
L2
R
BM
R
Time Clock or Remote
(Purchase Separately –
Supplies Power to
Circulator Pump)
Fireman's Switch
Completes the heater
24 Volt AC Control
Board Circuit.
DO NOT connect this
circuit to Line Voltage!
Figure 24.
P/N 475114 Rev. F 8/2020

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mastertemp 125 hd461078460902461079460903

Table of Contents