Certification
6.2 EMC and Environmental Type Tests
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
42
Description
HV Impulse
Dielectric Strength
Test
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Levels
5 kV (Fail-Safe Relay output)
5 kV
5 kV
2 kV
2 kV
2 kV
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g @ 10 - 150 Hz
30 g @ 11 mS
RUGGEDCOM RX5000
Installation Manual, 01/2021, C79000-G8976-1058-13

Advertisement

Table of Contents