IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
a
Siemens-specified severity levels
IEEE 1613 EMC Type Tests
Note
The RUGGEDCOM RX5000 meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports.
RUGGEDCOM RX5000
Installation Manual, 01/2021, C79000-G8976-1058-13
Test
Voltage Dips
& Interrupts
Damped Oscillatory
Mains Frequency
Voltage
Ripple on DC
Power Supply
Dielectric Strength
HV Impulse
Description
ESD
Radiated RFI
Fast Transient
Oscillatory
6.2 EMC and Environmental Type Tests
Description
AC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
DC Power ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
AC Power ports
Earth ground ports
Signal ports
DC Power ports
AC Power ports
Certification
Test Levels
30% for 1 period,
60% for 50 periods
100% for 5 periods,
100% for 50 periods
2.5 kV common, 1 kV
differential mode @1 MHz
2.5 kV common, 1 kV
differential mode @1MHz
2.5 kV common, 1 kV
differential mode @1MHz
30 V Continuous,
300 V for 1 s
30 V Continuous,
300 V for 1 s
10%
2 kV (Fail-Safe
Relay output)
2 kV
2 kV
5 kV (Fail-Safe
Relay output)
5 kV
5 kV
Test Levels
+/-2 kV, +/-4 kV, +/- 8 kV
+/-4 kV, +/-8 kV, +/-15 kV
35 V/m
+/- 4 kV @ 2.5 kHz
+/- 4 kV
+/- 4 kV
+/- 4 kV
2.5 kV common mode @1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
Severity
Levels
3
3
3
4
4
3
41