Power-Down Instruction - Flex BMR 474 2001 User Manual

Test board
Table of Contents

Advertisement

Model
BMR 474 2001
4.2

Power-down instruction

28701-ROA1286016 Rev A
Iout max
0.6V≤ Vo ≤1.8V
Iomax=80A
1.8V < Vo ≤3.3V
Iomax=60A
Make sure Enable switch is set to OFF position
By default, the module is configured to set Vout with pin-strap resistors.
Make sure jumper in the position 10 is populated with desired Vout.
Connect power supply to connectors on position 1.
Connect load to connectors on position 2.
Connect the PMBus adapter/cable to the board.
Apply Vin = 6-15V through connectors on position 1.
Set Enable switch to ON position. The power good LED will give green
light.
Note: PG LED is powered by USB-PMBus adapter, so only connect demo
board with computer through adapter, LED will be lit when module Vout is
ready.
Then increase the load, and through K2 (position 7) to measure the Vout
and ripple.
Set Enable switch to OFF position
Turn off Vin
2021/4/25
Test Board User Guide BMR4742001
Switching frequency
0.6V≤ Vo ≤1.8V
f
=500kHz
sw
1.8V < Vo ≤3.3V
f
=800kHz
sw
Vin/Vout range
Vin =6-15 V
0.6V≤ Vo ≤2.5V
Vin=7.5-15V
2.5V < Vo ≤3.3V
8 (20)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Roa 170 0146016Roa 128 6016

Table of Contents