Atlantic Ultraviolet Sanidyne 40-0634A Owner's Manual

Atlantic Ultraviolet Sanidyne 40-0634A Owner's Manual

Uv portable area sanitizer with remote

Advertisement

Quick Links

Extensive Product Information Available at:
Ultraviolet.com
BuyUltraviolet.com
Document No. 98-1709A5 • March 2020 • ©2020 Atlantic Ultraviolet Corporation
Models
40-0634A (120v)
40-0674A (230v)
8 High Output
UV Lamps with
ArmorLite™
Lamp Safety
Shield
Installation,
Operation &
Maintenance
Read and Follow All
Safety Instructions.
Save These Instructions.
®
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sanidyne 40-0634A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Atlantic Ultraviolet Sanidyne 40-0634A

  • Page 1 8 High Output UV Lamps with ArmorLite™ Lamp Safety Shield Installation, Operation & Maintenance Read and Follow All Safety Instructions. Save These Instructions. Extensive Product Information Available at: Ultraviolet.com BuyUltraviolet.com Document No. 98-1709A5 • March 2020 • ©2020 Atlantic Ultraviolet Corporation ®...
  • Page 2: Table Of Contents

    The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation and are believed to be correct. ® However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein.
  • Page 3: Safety Warnings

    SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
  • Page 4: Safety Labels

    SAFETY LABELS Danger Label: Ultraviolet Location of Danger Label (00-0195A2) on Both Sides of System Radiation (00-0195A2) Danger Label: Hazardous Location of Danger Labels (00-0197A2 and 00-0297) Voltage (00-0197A2) Hg-Lamp Contains Mercury Label (70-0011) Danger Label: Hazardous Voltage / Location of Danger Label (70-0038) on Both Sides of System Ultraviolet Radiation (70-0038) CAUTION It is the user’s responsibility to determine and validate the suitability of this equipment for use in the user’s system or...
  • Page 5: Product Applications

    PRODUCT APPLICATIONS onstruCtion The Sanidyne Prime Remote Portable Area Sanitizer consists of: ® • STER-L-RAY Germicidal ultraviolet lamps: Deliver ultraviolet energy at the specific wavelength of 254 nanometers (nm). ® This wavelength is highly effective against microbes including virus, bacteria and mold spores. Germicidal ultraviolet rays are harmful to eyes and skin, avoid exposure of direct or reflected germicidal ultraviolet rays without approved ultraviolet blocking face shield and protective covering (such as gloves, long sleeves with no gaps between cuff and gloves).
  • Page 6: Unpacking

    • Remove the Sanidyne Prime Remote from its shipping carton. ® • Atlantic Ultraviolet Corporation takes all possible precautions when packaging this unit to prevent damage. Carefully inspect ® the unit, power cord and plug for damage, report all damage immediately. Do not assemble or operate if there is any damage, visible or suspected.
  • Page 7: Verview

    eyPaD ontroller verview Figure 2 – Keypad Controller Overview 1. Treatment Time: Displays chosen treatment time which will countdown after start is selected. Flashes with word “PREP” during Countdown Time, the word “RUN” during Treatment Time and “DONE” when Treatment Time is completed. 2.
  • Page 8: And Eld Emote Ontroller

    emote ontroller verview Figure 3 – Hand-held Remote Controller Overview General Rule of Selection: Except for the ON/OFF button located on the top-right edge of the Hand-held Remote Controller, all selections made to this device will require a gentle touch of a short period of time to achieve a response. 1.
  • Page 9: Amp Nstallation

    6. Start Button: Starts treatment cycle time. Once selected: a) Remaining Time changes to Countdown Time and begins counting down from 1:29 minutes to exit area b) The words “LEAVE AREA” appear on the lower status bar. c) Alarm on unit begins to sound d) The word “PREP”...
  • Page 10: Nit Lacement

    Step 3 - Once pins are aligned Step 4 - Applying pressure Step 5 - Install the remaining seven correctly, press lamp base into lamp with your thumb on outside of lamps as described in steps 1– 4. socket until it is properly seated. Sanidyne Prime Remote, ®...
  • Page 11: Sanidyne Prime ® Remote O Peration

    aniDyne rime emote Peration ® The Sanidyne Prime Remote has two methods of controlling the unit; the Keypad Controller (Shown in Figure 2) and the ® Hand-held Remote Controller (Shown in Figure 3). These two controls mirror each other; treatment times entered into Keypad Controller will appear on the Hand-held Remote Controller and vice versa.
  • Page 12: D Ate

    NOTE: Once you select the start button an audible exit alarm will begin to sound and the Sanidyne Prime Remote ® will begin counting down from 1:30 seconds to allow all inhabitants to leave the area before the UV treatment begins. The words “LEAVE AREA”...
  • Page 13: D Etermining T Reatment T

    etermining reatment ime for izes The Sanidyne is intended for use in UNOCCUPIED AREAS ONLY. Under no Prime Remote ® circumstances should this unit be permitted to operate with humans, plants or animals present in the Operation Area. Consult our UV Application Specialists if you have any questions or need help with the Sanidyne Prime Remote.
  • Page 14: Maintenance

    MAINTENANCE IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES, LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN. Always disconnect power to the fixture before performing any service or maintenance. •...
  • Page 15: Use Eplacement

    ePlaCement The fuse is contained in a small plastic tray at the bottom of the power connector. Remove the power connector from the back of the Sanidyne Prime Remote. A screwdriver can be used to access the fuse ® by inserting the blade in one of the horizontal slots and gently twisting the handle to bring the tray forward. 2.
  • Page 16: Technical Specifications

    Prime Remote but additional signs may be purchased. ® For more information and purchasing contact our offices, weekdays between 8:30 am and 5:00 pm Eastern time, at: Atlantic Ultraviolet Corporation , 375 Marcus Boulevard, Hauppauge, New York, 11788 ® Tel: 631.273.0500 • Fax: 631.273.0771 • Email: Sales@AtlanticUV.com • Website: Ultraviolet.com – BuyUltraviolet.com...
  • Page 17: Replacement Parts

    Promate Face Shield & Adjustable Headgear 00-0126 00-0126 Promate Warning Sign 8.5’’ x 11’’ 00-0098 00-0098 Fuse 35-0644 35-0664 Other replacement parts are available. Consult Atlantic Ultraviolet Corporation for specific requirements. ® MAINTENANCE LOG Date Maintenance Performed Service Person Comment(s)
  • Page 18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment(s)
  • Page 19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment(s)
  • Page 20: User Assistance

    WARRANTY & PRODUCT REGISTRATION We warrant this product to the original owner to be free from defects in material and workmanship when installed in accordance with Atlantic Ultraviolet Corporation specifications for a period of time as follows: ®...

This manual is also suitable for:

Sanidyne 40-0674a

Table of Contents