....................................16 ....................................atent otiCe These instructions generally describe the installation, operation and maintenance of the Sanidyne Portable Area Sanitizer. ® Questions that are not specifically answerable by these instructions should be directed to the factory. atlantic ultraviolet corporation takes all possible precautions when packaging equipment to prevent damage.
SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
® • Atlantic Ultraviolet Corporation takes all possible precautions when packaging this unit to prevent damage. Carefully inspect the unit, power cord and plug for damage, report all damage immediately. Do not assemble or operate if there is any damage, visible or suspected.
• Portable Area Sanitizer does not require professional installation. ® For maximum efficiency the Sanidyne should be located as centrally as possible, in the area to be treated. The Sanidyne • ® ® Portable Area Sanitizer is most effective when it is located in the center of the room and the ultraviolet rays are unobstructed.
nstruCtions Step 1 - Disconnect Power to the sanitizer Step 2 - Release Latches Step 3 - Loosen Four Thumbscrews caution: Germicidal lamps are easily damaged. Exercise care when handling lamps. (See step 1 under Lamp Installation) warning: disconnect power cord. Remove protective storage cover by releasing the three laches on the storage cover.
Wear personal protection equipment; Gloves, long sleeve shirt with no gaps between cuffs and gloves, and an ultraviolet blocking face shield MuSt be worn to cover and protect eyes and all exposed skin. Although the cover must be fitted before testing the Sanidyne , the operator must also put on the safety face shield ®...
® unoccuPied space to disinfect areas and surfaces from microorganisms. Consult our Application Specialists if you have any questions or need help with the Sanidyne ® Figure 3 - Recommended Treatment Time for Room Sizes...
The fuse is contained in a small plastic tray at the bottom of the power connector. Remove the power connector from the back of the Sanidyne . A screwdriver can be used to access the fuse ®...
Power Cord 35-1754 35-1767 35-1767 Adjustable Headgear 00-0094 00-0094 00-0094 Face Shield 00-0095 00-0095 00-0095 Warning Sign 8.5’’ x 11’’ 00-0098 00-0098 00-0098 Fuse 35-0644 35-0644 35-0644 Other replacement parts are available. Consult the Atlantic Ultraviolet Corporation for specific requirements.
Under no circumstances shall the Atlantic Ultraviolet Corporation be liable for any incidental, consequential or special damages, losses or expenses arising from the contract for this product, or in connection with the use of, or inability to use, our product for any purpose whatsoever.