Atlantic Ultraviolet Sanidyne Prime 40-0633A Owner's Manual

Atlantic Ultraviolet Sanidyne Prime 40-0633A Owner's Manual

Ultraviolet portable area sanitizers

Advertisement

Quick Links

Models
40-0633A (120v)
40-0673A (230v)
8 High Output
UV Lamps with
ArmorLite™
Lamp Safety
Shield
Installation,
Operation &
Maintenance
Read and Follow All
Safety Instructions.
Save These Instructions.
DANGER
!
Ultraviolet
Radiation
UV
Extensive Product Information Available at:
Protect eyes and
Ultraviolet.com
skin from direct and
Buyultraviolet.com
reflected radiation.
1
Document No. 98-1692B5 • May 2020 • ©2020 Atlantic Ultraviolet Corporation
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sanidyne Prime 40-0633A and is the answer not in the manual?

Questions and answers

Summary of Contents for Atlantic Ultraviolet Sanidyne Prime 40-0633A

  • Page 1 Read and Follow All Safety Instructions. Save These Instructions. DANGER Ultraviolet Radiation Extensive Product Information Available at: Protect eyes and Ultraviolet.com skin from direct and Buyultraviolet.com reflected radiation. Document No. 98-1692B5 • May 2020 • ©2020 Atlantic Ultraviolet Corporation ®...
  • Page 2: Table Of Contents

    Follow all instructions on any labels or tags. Carefully inspect all packing materials before discarding to prevent the loss of accessories, mounting hardware, spare parts or instructions. The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation and are believed to ®...
  • Page 3: Safety Warnings

    SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
  • Page 4: Safety Labels

    SAFETY LABELS Safety Label: Warning: Location of Safety Label (70-0052) Ultraviolet Radiation (70-0052) Safety Label: Danger: Location of Safety Labels (00-0197A2 and 70-0011) Hazardous Voltage (00-0197A2) Hg-Lamp Contains Mercury Label (70-0011) Safety Label: Danger: Hazardous Voltage / Location of Safety Label (70-0038) on Both Sides of Unit Ultraviolet Radiation (70-0038) CAUTION It is the user’s responsibility to determine and validate the suitability of this equipment for use in the user’s system or...
  • Page 5 SAFETY LABELS The Sanidyne Prime Protective Cover should be used to hold Danger (2) Promate™ Laminated Danger ® Signs and additional Danger Labels. Place Protective Cover in location Signs (00-0098 / 00-0456) Front in blocking entrance to area being sanitized, as shown below. English, back in Spanish 8.5”x11”.
  • Page 6: Product Applications

    PRODUCT APPLICATIONS onstruCtion The Sanidyne Prime Portable Area Sanitizer consists of: ® Germicidal Ultraviolet Lamps: Deliver ultraviolet energy at the specific wavelength of 254 nanometers (nm). • STER-L-RAY ® This wavelength is highly effective against microbes including: virus, bacteria, and mold spores. •...
  • Page 7: Unpacking

    Prime from its shipping carton. ® • Atlantic Ultraviolet Corporation takes all possible precautions when packaging this fixture to prevent damage. Carefully ® inspect the unit, power cord and plug for damage, report all damage immediately. Do not assemble or operate if there is any damage, visible or suspected.
  • Page 8: Nit Lacement

    laCement • The Sanidyne Prime Portable Area Sanitizer does not require professional installation. ® • The Sanidyne Prime is intended for use in UNOCCUPIED AREAS ONLY. Under no circumstances ® should this sanitizer be permitted to operate with humans, plants, or animals present in the Operation Area. •...
  • Page 9: Sanidyne Prime Operation

    SANIDYNE PRIME OPERATION ® eyPaD ontroller verview Figure 2 – Timer Configuration Treatment Time: Displays chosen treatment time which will countdown after start is selected. Flashes with word “PREP” during Countdown Time, the word “RUN” during Treatment Time and “DONE” when Treatment Time is completed. Hour Buttons: Up and down buttons are used to select treatment hours between 0 and 24.
  • Page 10 Press the START button again to pause the exit warning. Confirm that the beeping stops. Press the START button again to restart the exit time. At the end of the 1-minute, 30-second exit time, the audible alarm will stop and the POWER indicator light will start flashing. The STER-L-RAY Germicidal Lamps should then switch on for the time set in the digital treatment time display.
  • Page 11: Reatment Ycle

    reatment yCle IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES, LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN. When the treatment time has been determined, set the Sanidyne Prime on a cleared table or on the floor in the center ®...
  • Page 12: Reakage

    5. Re-install the top cover and tighten the four thumbscrews. 6. Replace the storage cover and secure using the three latches. 7. Reconnect Sanidyne Prime to utility power, and restart. ® Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal ultraviolet rays are harmful to the eyes and skin.
  • Page 13: F Use R Eplacement

    ePlaCement The fuse is contained in a small plastic tray at the bottom of the power connector. Remove the power connector from the back of the Sanidyne Prime. A screwdriver can be used to access the fuse ® by inserting the blade in one of the horizontal slots and gently twisting the handle to bring the tray forward. 2.
  • Page 14: Optional Accessories

    Danger Labels 5.5”x 4.25” (1 English /1 Spanish) 70-0059 70-0059 Danger Ultraviolet Radiation Label 5”x 5” (English) 00-0358 00-0358 Danger Ultraviolet Radiation Label 5”x 5” (Spanish) 70-0060 70-0060 Fuse 35-0644 35-0664 Other replacement parts are available. Consult the Atlantic Ultraviolet Corporation for specific requirements. ®...
  • Page 15: Maintenance Log

    MAINTENANCE LOG Date Maintenance Performed Service Person Comment(s)