Premium ® Portable Area Sanitizer. Questions that are not specifically answerable by these instructions should be directed to the factory. Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent ® damage. Carefully inspect and report all damages. Do not install damaged equipment. Follow all instructions on any labels or tags.
SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
SAFETY LABELS Danger Label: Ultraviolet Radiation (70-0052) Danger Label: Hazardous Voltage / Ultraviolet Radiation (70-0036) Location of Danger Labels (70-0052) on Top of Unit Warning Germicidal UV Label (70-0037) DANGER Ultraviolet Radiation Protect eyes and Hg-Lamp Contains Mercury Label (70-0011) skin from direct and reflected radiation.
PRODUCT APPLICATIONS onstruCtion The Sanidyne Premium Germicidal Ultraviolet Portable Area Sanitizer consists of: ® • STER-L-RAY Amalgam Germicidal Ultraviolet Lamps: Deliver ultraviolet energy at the specific wavelength of 254 ® nanometers (nm). This wavelength is highly effective against microbes including virus, bacteria and mold spores. Germicidal ultraviolet rays are harmful to eyes and skin, avoid exposure of direct or reflected germicidal ultraviolet rays without approved ultraviolet blocking face shield and protective covering (such as gloves, long sleeves with no gaps between cuff and gloves).
• Remove the Sanidyne Premium from its shipping carton. ® • Atlantic Ultraviolet Corporation takes all possible precautions when packaging this fixture to prevent damage. Carefully ® inspect the unit, power cord and plug for damage, report all damage immediately. Do not assemble or operate if there is any damage, visible or suspected.
Figure 2 – Rear View of Unit eyPad ontroller verview Figure 3 – Keypad Controller Overview Treatment Time Displays HOURS: MINUTES TREATMENT TIME Power Indicator Hours Button Glows RED when power Up and Down Arrows set is applied, flashes during time from 0 to 24 Hours HOURS MINUTES...
Page 8
Held emote ontroller verview Figure 4 – Hand-held Remote Controller Overview Charging Port Battery Condition Settings Button Used to define treatment Displays Remaining Time and time in Hours : Minutes toggles to Countdown Time shown on Cycle Time Hours : Minutes : Seconds LampControl Treatment Time Begins at ( 1:29 ) minutes when pressed...
7. Pause / Continue Button: Used to pause the treatment time, or to continue the treatment time. This button toggles from the Pause Icon, which is displayed as two vertical bars to the Continue Icon which is a looping arrow. If pause is selected below 30 seconds during the Countdown, the Countdown time will reset to 30 seconds.
Step 4 – Using the lamp, apply Step 5 – Repeat until all lamps Step 6 – Once complete, reinstall slight pressure to compress the lower have been installed. Top Cover. lampholder, and then pivot the lamp so it aligns with the top lamp socket. Lamp should appear straight when it is correctly in place.
anidyne remium Peration ® The Sanidyne Premium has two methods of controlling the fixture; the Keypad Controller (Shown in Figure 3) and the ® Hand-held Remote Controller (Shown in Figure 4). These two controls mirror each other; treatment times entered into Keypad Controller will appear on the Hand-held Remote Controller and vice versa.
NOTE: Once you select the start button an audible exit alarm will begin to sound and the Sanidyne Premium will begin ® counting down from 1:30 seconds to allow all inhabitants to leave the area before the UV treatment begins. The words “Leave Area”...
etermining reatment ime for izes The Sanidyne is intended for use in UNOCCUPIED AREAS ONLY. Under no circumstances Premium ® should this unit be permitted to operate with humans, plants or animals present in the Operation Area. Consult our UV Application Specialists if you have any questions or need help with the Sanidyne ®...
MAINTENANCE IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES, LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN. Always disconnect power to the fixture before performing any service or maintenance. •...
TROUBLESHOOTING Always disconnect power to the fixture before performing any service or maintenance. IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES, LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN. IMPORTANT: This fixture is to be serviced ONLY by qualified and factory authorized personnel.
Part No. STER-L-RAY Germicidal Lamp 05-0250 ® Surelite ™ Ballast 10-0255 Cooling Fan Guard with Filter 40-1467 Line Cord : 10ft, 20A, 120v 35-2122 Fuse: 250v 20A 35-2123 Other replacement parts are available. Consult Atlantic Ultraviolet Corporation for specific requirements. ®...
WARRANTY & PRODUCT REGISTRATION We warrant this product to the original owner to be free from defects in material and workmanship when installed in accordance with Atlantic Ultraviolet Corporation specifications for a period of time as follows: ®...