Atlantic Ultraviolet Sanidyne User Manual

Portable area sanitizer
Hide thumbs Also See for Sanidyne:

Advertisement

Quick Links

Sanidyne
P O R TA B L E A R E A S A N I T I Z E R
Sanidyne
375 Marcus Boulevard
Hauppauge, NY 11788
USA
631.273.0500
Fax: 631.273.0771
e-mail: info@ultraviolet.com
Extensive Product Information Available at:
www.ultraviolet.com
Document No. 98 -1196B1 • Revised September 2007 • © 2001-2007 Atlantic Ultraviolet Corporation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sanidyne and is the answer not in the manual?

Questions and answers

Summary of Contents for Atlantic Ultraviolet Sanidyne

  • Page 1 P O R TA B L E A R E A S A N I T I Z E R Sanidyne 375 Marcus Boulevard Hauppauge, NY 11788 • • 631.273.0500 Fax: 631.273.0771 • e-mail: info@ultraviolet.com Extensive Product Information Available at: www.ultraviolet.com Document No. 98 -1196B1 • Revised September 2007 • © 2001-2007 Atlantic Ultraviolet Corporation...
  • Page 2: Table Of Contents

    7. MAINTENANCE ..............................5 8. SPECIFICATIONS ..............................6 9. REPLACEMENT PARTS ............................6 RECOMMENDED TREATMENT FOR VARIOUS ROOM SIZES..............7 WIRING DIAGRAMS ............................8 - 9 ® Sanidyne 120V................................ 8 ® Sanidyne 230V................................ 9 DIMENSIONAL DIAGRAMS ........................10 - 11 ®...
  • Page 3: Introduction

    Please read this manual in its entirety before use. 1. INTRODUCTION ® The Sanidyne Portable Area Sanitizer disinfects air and surfaces in unoccupied areas by means of four germicidal lamps. The lamps generate high levels of ultraviolet radiation lethal to bacteria, molds, viruses, and fungi.
  • Page 4: Set-Up Procedure

    3.5.4 Ensure that all four lamps are lit through the observation windows in the cover. 3.5.5 Replace the protective storage cover when the unit is not in use. 4. APPLICATIONS ® Typical applications for the Sanidyne Portable Area Sanitizer include the following: • Operating rooms • Patient rooms •...
  • Page 5: Troubleshooting

    6. TROUBLESHOOTING Problem Possible Cause Action 1. One lamp does not light a. Lamp burned out or lamp defective a. Swap suspect lamp with another and confirm b. Lamp installed improperly that it is inoperative. Replace lamp if necessary. c. Loose electrical connection b.
  • Page 6: Specifications

    8. SPECIFICATIONS Volts : 120V 220-240V Amps : 1.7A 1.8A Hertz: 60 Hz 50/60 Hz Maximum Treatment Time : 3 hours Maximum Treatable Room Size : 58' L x 58' W x 20' H Total UV Lamp Watts : 77.2 W (19.3 W per lamp) Rated Lamp Life : 10,000 Hours Dimensions :...
  • Page 7: Recommended Treatment For Various Room Sizes

    RECOMMENDED TREATMENT TIME FOR VARIOUS ROOM SIZES Based on 8 Foot Ceiling Height LONGEST ROOM DIMENSION (FEET)
  • Page 8: Wiring Diagrams

    WIRING DIAGRAM ® Sanidyne 120V...
  • Page 9: Sanidyne ® 230V

    ® Sanidyne 230V...
  • Page 10: Dimensional Diagrams

    DIMENSIONAL DIAGRAM ® Sanidyne 120V...
  • Page 11: Sanidyne ® 230V

    ® Sanidyne 230V...
  • Page 12: Warranty

    Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage. Carefully inspect and report all damage. Do not install damaged equipment. Follow all instructions on any labels or tags.