3.3.2

FSA 740 Edition rear view

8
Fig. 2:
FSA 740 Edition rear view without rear wall
1 Measuring unit
2 PC
3 Printer (PDR 377)
4 BEA 055
1)
5 ON / OFF switch with socket strip
6 Cover panel
7 KTS modul
1)
8 WLAN USB adapter
)
sometimes provided as special accessory
1)
3.3.3
Measurement lead with
The measurement lead with voltage divider
(1 687 224 300) is used for voltage measurements up
to 60 VDC/30 VAC/300 VACpeak. The accessory set
(1 687 016 118) contains test prods (1 684 485 434/
... 435) and pick-off clips (1 684 480 403/ ... 404) as
accessories for the measurement lead with voltage
divider. Never use the measurement lead with voltage
divider to measure mains or similar voltages.
Robert Bosch GmbH
4597758/3Wo
voltage divider xxx
| FSA 740 Edition | 21
3.3.4

FSA 740 Edition terminal strip

DANGER – Risk of electric shock from ex-
cessively high measurement voltage.
The measurement of voltages in excess of
60 VDC/30 VAC/42 VACpeak using Multi
measurement leads CH1 / CH2 will result in
injury, heart failure or fatal electric shocks.
Never use Multi measurement leads CH1 /
CH2 to measure mains or similar voltages.
KV-
COM
15+
- 1
1
2
3
4
5 6 7 8 9 10 11 12 13 14
Fig. 3:
FSA 740 Edition terminal strip (from below)
1 Temperature sensor
2 Connecting cable B+/B–
3 Primary connecting cable (UNI 4)
4 Trigger clamp or
adapter line 1 684 465 513 for clip-on sensor
5 RS 232 serial interface (no function)
6 Sensor KV–
7 USB connection for data connection PC
8 Sensor KV+
9 Power supply for measuring unit (power pack)
10 Multi measurement lead CH1 or measurement lead with voltage
divider or current probe 30 A
11 Multi measurement lead CH2 or measurement lead with voltage
divider or current probe 30 A or current probe 1000 A
12 Stroboscope
13 Air pressure measurement
14 Liquid pressure sensor
When the speed is being measured with the clip-on sensor,
1)
adapter line 1 684 465 513 must always be connected between
plug socket FSA 740 Edition and the connecting cables for the
clip-on sensor.
3.4

Special accessories

Information on special accessories, such as vehicle-
specific connecting leads, can be obtained from your
authorized Bosch dealer.
3.5

Socket

The rated voltage of 240 VAC and the rated
current of 13 A is defined for the multiple
socket outlet. Each rated values should not
be exceeded.
en
X
KV+
CH1
CH2
D
USB
15V DC
45977541-Ko
1)
1 689 989 089
|
2018-03-24