Measurement Of Main Circuit Voltages, Currents, And Powers - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

3.2
Measurement of main circuit voltages, currents,
and powers
Since the voltages and currents on the inverter power supply and output sides include harmonics, measurement data depends
on the instruments used and circuits measured. When instruments for commercial frequency are used for measurement,
measure the following circuits with the instruments given on the next page.
NOTE
• When installing meters etc. on the inverter output side
When the inverter-to-motor wiring length is long, especially in the 400 V class, small-capacity models, the meters and CTs may
generate heat due to line-to-line leakage current. Therefore, choose the equipment which has enough allowance for the
current rating.
To measure and display the output voltage and output current of the inverter, it is recommended that the terminal AM and FM
output functions of the inverter are used.
Three-phase power input
Single-phase power input
Three-phase
power supply
52
3. Precautions for Maintenance and Inspection

3.2 Measurement of main circuit voltages, currents, and powers

Input voltage
Input current
Ar
W11
Vr
As
W12
*
*
Vs
*
At
W13
*
*
Vt
*
* At, As, Vt, Vs, W12, W13 are only for the three-phase power input specification models.
Inverter
Au
R/L1
U
W21
Vu
Av
S/L2
V
Vv
Aw
W
T/L3
W22
Vw
P/+
N/-
V
+
-
Output voltage
Output current
To the motor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents