Power Cord; Refrigerant Cycle; Condenser - Friedrich Z-Star ZQ05C10 Service And Parts Manual

115 volts
Hide thumbs Also See for Z-Star ZQ05C10:
Table of Contents

Advertisement

2.3.6 POWER CORD

1. Disconnect the unit from source of power.
2. Remove the front grille. (Refer to Section 2.1.1)
3. Remove the cabinet. (Refer to Section 2.1.2)
4. Remove a screw that secures control panel to
base pan. (Refer to Section 2.1.3)
5. Pulls the control panel toward you.
6. Disconnect the 2 receptacles and remove the
grounding screw.
7. Remove a screw securing the cord clip to the
control board.
8. Pull the power cord.
9. Re-install by referring to procedures above.
2.4 REFRIGERATION SYSTEM

2.4.1 CONDENSER

1. Remove the cabinet. (Refer to Section 2.1.2)
2. Discharge the refrigerant by using a refrigerant
recovery system.
3. Remove the air guide. (Refer to Section 2.2.1)
4. Remove 2 screws which fasten the condenser.
5. After discharging the refrigerant completely,
unbraze the interconnecting tube at the
condenser connections.
6. Remove the condenser.
7. Re-install by referring to the procedures above.
Figure 18
Figure19
—9—