Setting level
d.24 Status of the pressure
switch
d.25 Status of the requirement
to reheat the cylinder or for
the domestic hot water warm
start from the eBUS thermo-
stat
d.27 Function of relay 1 (multi-
functional module)
d.28 Function of relay 2 (multi-
functional module)
d.31 Automatic filling device
d.33 Fan speed target value
d.34 Value for the fan speed
d.40 Heating flow temperature
d.41 Heating return temperat-
ure
d.43 Heat curve
d.45 Value for the base point
of the heat curve
d.47 Outdoor temperature
d.50 Correction of the min-
imum fan speed
d.51 Correction of the max-
imum fan speed
d.58 Solar circuit reheating
d.60 Number of blocks by the
temperature sensor
d.61 Number of unsuccessful
ignitions
d.62 Night set-back
d.64 Average burner ignition
time
d.65 Maximum burner ignition
time
40
Values
Unit
Min.
Max.
0
1
Current value
1
10
1
10
0
2
Current value
rpm
Current value
rpm
Current value
Current value
0.2
4
15
30
Current value
0
3000
rpm
-2500
0
rpm
0
3
Current value
Current value
0
30
Current value
s
Current value
s
Increment, select, explanation
off = Not switched
on = Switched
off = Function deactivated
on = Function activated
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extraction hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (omitted)
8 = eBUS remote control
9 = Anti-legionella pump
10 = Solar valve
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extraction hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (omitted)
8 = eBUS remote control
9 = Anti-legionella pump
10 = Solar valve
0 = Manual
1 = Semi-automatic
2 = Automatic
Fan speed = Display value x 100
Fan speed = Display value x 100
0.1
1
1
Fan speed = Display value x 10
1
Fan speed = Display value x 10
0 = Boiler's anti-legionella function
deactivated
3 = Domestic hot water activated (tar-
get value min. 60 °C)
1
Installation and maintenance instructions ecoFIT pure 0020230535_07
Default set-
Own setting
ting
Not
adjustable
Not
adjustable
1
Adjustable
2
Adjustable
0
Adjustable
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
1.2
Adjustable
20
Adjustable
Not
adjustable
600
Adjustable
-1000
Adjustable
0
Adjustable
Not
adjustable
Not
adjustable
0
Adjustable
Not
adjustable
Not
adjustable