6

Set-up

6.1

Checking the scope of delivery

Check that the scope of delivery is complete and intact.
6.1.1
Scope of delivery
Num-
Designation
ber
Heat generator
1
Unit mounting bracket
1
1
Flue adapter
Gas stopcock
1
1
Gas pipe
1
Condensate discharge hose
1
Mounting template
1
Enclosed documentation
0020230535_07 ecoFIT pure Installation and maintenance instructions
6.2

Dimensions

183,5
375
33,5
78
220
1
Condensate discharge
2
Gas connection
3
Heating return
6.3

Installation site

This boiler is not suitable for outdoor installation. This boiler
may be installed in any room. However if the boiler is being
installed in a room containing a bath or shower it must only
be installed in zones 2 or 3. In GB this is the current I.E.E.
WIRING REGULATIONS and BUILDING REGULATIONS. In
IE reference should be made to the current edition of I.S.813
"Domestic Gas Installations" and the current ETCI rules.
If the boiler is to be installed in a timber frame building it
should be fitted in accordance with the current version of the
Institute of Gas Engineers document IGE/UP/7. If in doubt
seek advice from local gas undertaking or the manufacturer.
1
2
71
3
133,5
4
5
6
4
Heating flow
5
Rear air/flue connection
6
Top air/flue connection
13