7.10.4 Establishing the power supply
1
1.
Observe all valid regulations.
2.
Ensure that the nominal mains voltage is 230 V.
3.
Do not interrupt the mains supply with a time switch or
programmer.
4.
Set up a fixed connection and install a partition with
a contact gap of at least 3 mm (e.g. fuses or power
switches).
5.
Isolation should preferably be by a double pole
switched fused spur box having a minimum contact
separation of 3mm on each pole. The fused spur box
should be readily accessible and preferably adjacent to
the boiler. It should be identified as to its use.
6.
Provide one common power supply for the boiler and
for the corresponding control:
Power supply: Single-phase, 230 V, 50 Hz
Fuse protection: ≤ 3 A
7.
Open the electronics box. (→ Page 24)
8.
Observe the routing of the power supply cable (1) in the
electronics box in order to guarantee that there is no
strain.
0020230535_07 ecoFIT pure Installation and maintenance instructions
9.
Carry out the wiring. (→ Page 24)
10. Close the electronics box.
11. Make sure that access to the power supply is always
available and is not covered or blocked.
7.10.5 Connecting the heating pump
Connect the heating pump to the boiler; see the wiring
diagram in the appendix.
7.10.6 Connecting controls to the electronics
1
Safety thermostat for
underfloor heating
2
24 V control
1.
Open the electronics box. (→ Page 24)
2.
Carry out the wiring. (→ Page 24)
3.
Connect the individual components depending on the
installation type.
X1
L
N
RT
230V~
24 V
BUS
+
Burner
24V=
off
RT
BUS
1
2
3
X2
X41
X22
4
3
eBUS control or radio
receiver unit
4
Outdoor temperature
sensor, wired