Instron 34SC-05 Preinstallation Manual

Instron 34SC-05 Preinstallation Manual

Single column table model
Hide thumbs Also See for 34SC-05:

Advertisement

Quick Links

Model 34SC-05 Single Column Table Model
Preinstallation Manual
M10-17314-EN
Revision B

Advertisement

Table of Contents
loading

Summary of Contents for Instron 34SC-05

  • Page 1 Model 34SC-05 Single Column Table Model Preinstallation Manual M10-17314-EN Revision B...
  • Page 2 Instron is a registered trademark of Illinois Tool Works Inc. (ITW). Other names, logos, icons and marks identifying Instron products and services referenced herein are trademarks of ITW and may not be used without the prior written permission of ITW.
  • Page 3 Caution is used where a hazard may lead to damage to equipment or to loss of data. Instron products, to the best of its knowledge, comply with various national and international safety standards, in as much as they apply to materials and structural testing.
  • Page 4 Preliminary Pages Warnings Hazard - Press the Emergency Stop button whenever you consider that an unsafe condition exists. The Emergency Stop button removes hydraulic power or electrical drive from the testing system and brings the hazardous elements of the system to a stop as quickly as possible.
  • Page 5 During system operation, keep away from the operating envelope of the robot. De-activate the robot before entering the envelope for any purpose, such as reloading the specimen magazine. Product Support: www.instron.com...
  • Page 6 Preliminary Pages Warnings Hazard - Set the appropriate limits before performing loop tuning or running waveforms or tests. Operational limits are included within your testing system to suspend motion or shut off the system when upper and/or lower bounds of actuator or crosshead travel, or force or strain, are reached during testing.
  • Page 7 Apply the specified torque to all load string fasteners and the correct setting to wedge washers or spiral washers. Visually inspect highly stressed components such as grips and threaded adapters prior to every fatigue test for signs of wear or fatigue damage. Product Support: www.instron.com...
  • Page 8 Preliminary Pages M10-17314-EN...
  • Page 9: Table Of Contents

    34SC-05 Power Requirements and Cords ........
  • Page 10 34SC-05 Packaging dimensions and weight ........
  • Page 11 • system performance specifications for this frame model Refer to the Operator’s Guide for instructions on connecting system components, system configuration, running tests, and performing routine maintenance of the system. Product Support: www.instron.com...
  • Page 12: Chapter 1: Introduction

    Chapter: Introduction System Description and Terminology ® Figure 1. 3400 Single Column Table Model with Bluehill Operator Dashboard - Front View M10-17314-EN...
  • Page 13 System Description and Terminology Legend for Figure 1 Label Component Ballscrew cover Top plate Column cover Load cell Upper limit switch Limit switch actuator Lower limit switch Emergency stop button Frame control panel ® Bluehill Operator Dashboard (optional) Product Support: www.instron.com...
  • Page 14 Chapter: Introduction Figure 2. 3400 Single Column Table Model - Rear View M10-17314-EN...
  • Page 15: Components

    ® contacting extensometer. Contact your regional Instron office or check our web site at www.instron.com for assistance with Instron’s grips and fixtures. The following table defines the components of the testing system: Product Support: www.instron.com...
  • Page 16: Principle Of Operation

    The load cell converts this load into an electrical signal that the software measures and displays. ® ® Bluehill Instron Software testing software that controls the testing system, running tests and analyzing test data to produce test results. Specimen A single piece of material to be tested.
  • Page 17: Software

    Frame control panel - holds all the controls and indicators for the testing system. Software ® Control of the testing system is carried out via Instron Bluehill software. Setting test parameters, operating the system, and collecting test data is done through the software program.
  • Page 18 Chapter: Introduction Table 3. Safety and Information Labeling Descriptions (Continued) Label Meaning Purpose Disconnect power Disconnect the power supply before supply servicing machine. Electrical - fuse warning Indicates an electrical hazard exists. Advises disconnecting power mains before changing fuses and using only specified fuses.
  • Page 19: Product Support

    ® If you cannot find answers in these sources, contact Instron Service directly. A list of ® Instron offices is available on our website at www.instron.com. In the US and Canada, you can call directly at 1-800-473-7838. Product Support: www.instron.com...
  • Page 20: Product Documentation

    ® Instron offers a comprehensive range of documentation to help you get the most out of your Instron products. Depending on what you have purchased, your documentation may include some or all of the following: Operator’s Guide How to use your system components and controls, procedures for setting limits, calibration and other frequently performed operating tasks.
  • Page 21: Chapter 2: Requirements

    Environmental specifications ......... 26 • 34SC-05 Power Requirements and Cords ....... 28 •...
  • Page 22: Supplier's Responsibilities

    Under Instron’s standard contract, the shipping terms are Ex-Works (or FOB Factory), meaning ownership and liability for the testing system transfers to the customer at Instron’s loading dock. Unless other shipping terms are specified in a purchase order, which Instron does not dispute, the Ex-Works shipping terms apply. Under these terms, the customer is responsible for securing the applicable transit insurance on the shipment and arranging safe transport to the final destination.
  • Page 23: Site Requirements

    Site requirements Instron is responsible for insurance cover while the testing system is in the factory up until it reaches the loading dock for shipping. Installation When the site location is prepared and the frame and its components have been moved ®...
  • Page 24: Frame Location

    ® Instron systems require “clean” and stable electrical power. Unless other ® arrangements are made with Instron , you are responsible for providing clean electrical power. An in-line power surge protector is recommended for all installations. M10-17314-EN...
  • Page 25: Telephone And Network Access

    Our goal is to provide remote diagnostics in order to resolve system issues. ® Having a network drop or digital phone line available will enable an Instron service representative to connect to the testing system to diagnose and resolve problems more efficiently.
  • Page 26: Environmental Specifications

    Chapter: Requirements Dry compressed air Dry, compressed air is required for pneumatic grips. Typically, 90 psi air is required with a water trap/filter. Water supply A water supply may be required for some specimen grips and some temperature control systems. Liquid nitrogen and carbon dioxide A liquid nitrogen (LN2) or carbon dioxide (CO2) supply may be required for environmental chambers with cooling options.
  • Page 27: Conformity With Eu Directives

    Care must be taken at the end of the equipment's life to ensure its disposal in accordance with local environmental regulations. Because of the wide range of applications where our instruments are used, Instron has no knowledge of the environmental impact of the customer's test pieces or specimens.
  • Page 28: 34Sc-05 Power Requirements And Cords

    The noise output from equipment used for materials or structures testing is also depen- dent upon the items under test. Instron recommends that users carry out their own noise level measurements to ensure the continuous safety and comfort of personnel.
  • Page 29: Power Cord Selections

    34SC-05 Power Requirements and Cords Power cord selections ® If you do not make a choice, Instron chooses the customary power cord that matches the shipping destination for the system. Table 6. Power cords Power cord designation Matching receptacle Locale...
  • Page 30: Checklist For Site Preparation

    Instron Service or your local Instron office for assistance. Not all computers are compatible with Instron testing systems. If you intend to purchase ® a computer from an outside vendor, contact Instron Service to verify its compatibility.
  • Page 31: Transporting

    Pathway from the loading dock to the final site location has sufficient width and height to fit the frame and forklift (or crane). Measure all doors and hallways. Refer to “34SC-05 Dimensions and Weight” on page for dimensions and weights of the testing system without its packaging. Refer to “34SC-05 Packaging...
  • Page 32: Scheduling Installation

    When the testing site is ready, and the frame has been moved to its final operating ® location, contact Instron to schedule an installation appointment. ® A list of Instron offices is available on our website at www.instron.com. In the United States and Canada, you can call 1-800-473-7838. M10-17314-EN...
  • Page 33: Chapter 3: Specifications

    34SC-05 Dimensions and Weight ........
  • Page 34 Chapter: Specifications Figure 3. 34SC-05 frame dimensions - front view M10-17314-EN...
  • Page 35 34SC-05 Dimensions and Weight Figure 4. 34SC-05 frame dimensions - side view Product Support: www.instron.com...
  • Page 36: System Weight

    Chapter: Specifications System weight Table 8. System weight Configuration Weight kg (lb) Standard load frame 49.9 (110) ® The weight value does not include additional accessories such as the Bluehill Operator Dashboard or any load cell. Accessory Mounting Dimensions You can attach numerous testing accessories and fixtures to the load frame for specialized tests.
  • Page 37: Base Beam Dimensions

    Accessory Mounting Dimensions Base beam dimensions 62.5 12 PCD 45° 45° 4X M6 55 PCD Figure 5. View of base beam from above 3.13 40.038 3.00 40.000 Figure 6. Cross-sectional view of base beam Product Support: www.instron.com...
  • Page 38: Crosshead Dimensions

    Chapter: Specifications Crosshead dimensions 45° 30° 4X M4X0.7 - 6H THRU ALL 16.6 45° 3.08 3.04 4X ON 16 PCD 4X ON 55 PCD 16 PCD 55 PCD Figure 7. View of underside of crosshead 22.00 11.06 11.00 3.10 3.00 40.038 40.000 Figure 8.
  • Page 39: System Performance

    System Performance System Performance Table 10. 34SC-05 system performance Parameter Specifications Testing type Tension, compression, and through zero operation. Basic control mode Closed loop position control Load capacity - kN (lbf) 0.5 (112) Maximum speed - mm/min (in/min) 1016 (40) Minimum speed - mm/min (in/min) 0.05 (0.002)
  • Page 40 Chapter: Specifications M10-17314-EN...
  • Page 41: Chapter 4: Risk Reduction And Safe Use

    • the experience of the operator using the equipment It is our strong recommendation, therefore, that you carry out your own risk assessment for your particular equipment setup and testing application. Product Support: www.instron.com...
  • Page 42: Rapid Crosshead Motion

    Chapter: Risk reduction and safe use Each of the following sections describes a specific hazard zone of the testing system and lists the most common risks for testing using this equipment. Use the information in the following sections, together with the instructions in the remainder of this manual, to conduct your own risk assessment.
  • Page 43 Use a specimen insertion tool to keep fingers out of the space between the fixtures. • Use an interlocked shield to limit or disallow motion when the shield door is open. When the space is less than 25mm, the crush hazard is very significant, so this is the best option. Product Support: www.instron.com...
  • Page 44: Pinching Fingers Between Grip Jaw Faces

    Chapter: Risk reduction and safe use Pinching fingers between grip jaw faces Warning Pinch hazard to fingers. This hazard relates to grip jaws closing quickly, pinching fingers. Recommendations For 2712 Series pneumatic grips: • In the documentation supplied with the grips, read and follow the safety recommendations for installing a specimen.
  • Page 45: Impact Of Debris From Breaking Specimens

    Hazard from flying debris. This hazard relates to brittle or composite specimens that can explode when they break. Recommendations For less dangerous debris (specimen dust or fibers, for example): • Use personal protection equipment (for example safety glasses). Product Support: www.instron.com...
  • Page 46: Operator Protection Overview

    Chapter: Risk reduction and safe use For more dangerous projectile debris (brittle composite specimens, for example): • Use an interlocked shield. Operator Protection Overview The majority of hazards for operating materials testing systems are associated with: • rapid movement of the crosshead causing crush injuries •...
  • Page 47 Operator Protection lets an Administrator configure the testing system to be consistent with the risk assessment for that system. Access to the controls for Operator Protection is password protected. If you have ® Administrator rights you can modify Operator Protection in the Admin tab in Bluehill Product Support: www.instron.com...
  • Page 48 Chapter: Risk reduction and safe use M10-17314-EN...
  • Page 49: Chapter 5: Lifting And Handling

    General handling precautions ........49 • 34SC-05 Packaging dimensions and weight ......49 •...
  • Page 50: Transport Single Column Frames

    The frame and forklift (or crane) can fit through all doorways, halls, elevators or stairs from the shipping dock to its final site location. Refer to “34SC-05 Dimensions and Weight” on page 33. If the frame is still in its packaging, check the packaging dimensions for your frame model. If you are moving the frame without its packaging, check the dimensions for your frame model.
  • Page 51: Transport Single Column Frames

    Count the number of boxes you received to make sure you have the correct number of boxes. Do not open these boxes until the Instron service representative arrives to install your testing system. This ensures that no parts are lost prior to installation.
  • Page 52 Chapter: Lifting and handling Figure 9. Eyebolt for lifting the frame For some systems, the eyebolt is removed prior to shipping. If the eyebolt is missing from your machine, it will be packed in an envelope inside one of the unsealed boxes, usually in the box that contains the system documentation.
  • Page 53: Index

    ......24 Instron......22 frame routine maintenance.
  • Page 54 telephone access ..... 25 M10-17314-EN...
  • Page 56 www.instron.com...