Connect each conductor (L, N, PE) to its appropriate terminal (L, N, PE). The coloring
and the positions may differ from Figure 59.
Caution!
Risk of electric shock and product damage.
Ensure the Power bar and the whole LED Wall are properly grounded before
putting it into use.

Check the Power Supply and Data Connection of the Modules

With the NovaLCT software, you can check whether the power supplies of each module work
properly and whether the data transmission between the cabinets works properly.
Install the Software, see 7.2 Install Controller Software NovaLCT.
Load the screen files, see 7.3 Configure the Screen in NovaLCT.
Connect the LED Wall to mains or turn it on.
Follow 8.3 Monitoring, section 8.3.2 to 8.3.3.
If you find an error, check the wiring and the connection of the Power supply
sockets.
Separate the LED Wall from mains power to continue safely with the installation.

6.5 Install Frame Covers

The frame covers protect the LED Wall from any dust or other particles that could come in
through the holes on the sides and the top.
Inside the frame covers are slot nuts. The frame covers are attached to the LED Wall via
screws, which go through the Screw connection anchors into the slot nuts.
Info
It is easier to install the frame covers first and later the Pixel cards. However, if the Pixel
cards are already installed, only a few Pixel cards need to be taken out to install the frame
covers. The pictures also show the procedure with installed Pixel cards.
This section is a guide through the assembly of the frame and its installation on the LED Wall.

Table 12: Frame Cover Installation Requirements

No. of People 2
Prerequisites Cabinets
Enough space in front of LED Wall to assemble frame
Tools
Screwdriver
Allen key
Service tool
Equipment
Frame covers:
 Side cover for Power bar
 Frame cover side (LED Wall)
 Frame cover top
 Frame cover links
 Power bar cover
© NEC Corporation 2019