Troubleshooting Chart - Campbell Hausfeld WL6000 Series Operating Instructions Manual

Oiless stationary compressors
Hide thumbs Also See for WL6000 Series:
Table of Contents

Advertisement

Available languages

Available languages

Operating Instructions
Oilless Stationary Compressors

Troubleshooting Chart

Symptom
Compressor will not run
Motor hums but cannot
run or runs slowly
Fuses blow/circuit
breaker trips repeatedly
Never use an extension
cord with this product
Thermal overload
protector cuts out
repeatedly
Knocks, rattles,
excessive vibration
Possible Cause(s)
1. No electrical power
2. Blown fuse
3. Breaker open
4. Thermal overload open
5. Pressure switch bad
6. Check valve defective
1. Poor contacts, line voltage incorrect
2. Shorted or open motor winding
3. Defective check valve or unloader
1. Incorrect size fuse, circuit overloaded
2. Defective check valve or unloader
1. Low voltage
2. Clogged air filter
3. Lack of proper ventilation/room
temperature too high
4. Check valve malfunction
1. Leaking, broken, or loose valves or
restricted air passage
2. Defective pressure switch unloader
3. Defective bearing on eccentric or
motor shaft
4. Cylinder or piston ring is worn or
scored
5. Loose bolts, tank not level
Corrective Action
1. Plugged in? Check fuse/breaker or motor overload.
2. Replace blown fuse
3. Reset, determine cause of problem
4. Motor will restart when cool
5. Replace
6. Remove and replace check valve
1. Check connections, check with voltmeter
2. Replace motor
3. Replace or repair
1. Check for proper fuse, use time-delay fuse.
Disconnect other electrical appliances from circuit or
operate compressor on its own branch circuit.
2. Replace or repair
1. Check with voltmeter
2. Clean filter (see Maintenance section)
3. Move compressor to well ventilated area
4. Replace
1. Replace
2. Replace or repair as necessary
3. Replace
4. Replace or repair as necessary
5. Tighten bolts, shim tank to level position
6
Do not disassemble check valve
with air in tank; bleed tank
Do not disassemble check valve
with air in tank; bleed tank
Do not disassemble check valve
with air in tank; bleed tank
Do not disassemble check valve
with air in tank; bleed tank

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents