Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip.
Note:
1HYHU FXW WKH SRZHU FRQQHFWLRQ ZLUH WR SURORQJ RU VKRUWHQ WKH GLVWDQFH
Step six: Arrange piping
1. The pipes should be placed along the wall,
bent reasonably and hidden
2. If outdoor unit placement is higher than wall
penetration, create a drip loop in the line-set to
keep water from entering the building.
Outdoor Condensate Drainage (only for Heat pump unit)
During heating operation, the condensate and
defrosting water should be drained out reliably
through the drain hose. Install the outdoor dr-
DLQ FRQQHFWRU LQ D
 KROH RU
base plate and attach the drain hose to the co-
nnector so that the waste water formed in the
outdoor unit can be drained out. The hole dia-
PHWHU  RU  PXVW EH SOXJJHG
Whether to plug other holes will be determined
by the dealers to actual conditions.
07
09 12K UNIT:
Drain-water hole
Bottom frame
18K UNIT:
 KROH on the
. 81,7
drain hole
13
8VKDSHG FXUYH
drain hose
drain hole
Drain-water hole
Bottom frame
Drain-water hole
Bottom frame
wall