LC modules
Use of the switching input JP2
According to the version you can control the program flow or choose
one of two different program variants via the switching input JP2.
According to the version and to the intended mode of operation you
can use switches, push-buttons or fixed solder connections. With some
versions JP2 has no function.
LC version
LC-12, LC-13, LC-17,
LC-19, LC-20
LC-1, LC-2, LC-3,
LC-4, LC-5, LC-6,
LC-8, LC-14, LC-15,
LC-21, LC-22, LC-23
LC-7
LC-9
LC-10
LC-11
LC-16
LC-18
* e.g. by closing a switch
Function of JP2
No effects on the program flow.
JP2 open à endless repeat.
JP2 is connected to earth* à The cycle will be
ended after the end of the program.
JP2 open à standard operation.
JP2 is connected to earth* à Traffic lights
switch to flashing amber.
JP2 is connected to earth for a short time (e.g.
by the switching impulse of a push-button)
à program will be started / finished.
JP2 is connected to earth for a short time (e.g.
by the switching impulse of a push-button)
à program will be started / finished.
JP2 is connected to earth à defective
fluorescent tube at output 5.
JP2 connected to earth à "Home".
JP2 open à "Office".
JP2 designed for the connection of a dim
switch.
JP2 connected to earth à "standing vehicle".
JP2 open à "moving vehicle".