Bosch AL 1810 CV Original Instructions Manual page 8

Hide thumbs Also See for AL 1810 CV:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
8 | English
Battery charger
– 18 V / 5.0 Ah
– 18 V / 6.0 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01:2014
Protection class
Operation
Start-up
Note the mains voltage! The voltage of the power source
u
must match the voltage specified on the rating plate of
the charger. Chargers marked with 230 V can also be op-
erated with 220 V.
Charging process
The charging process begins as soon as the mains plug for
the charger is inserted into the mains socket and the battery
(1) is inserted into the charging slot (2).
Thanks to the intelligent charging process, the charge condi-
tion of the battery is automatically detected and then
charged up with the optimal charge current depending on
battery temperature and voltage.
In this way, the battery is treated with care and remains per-
manently fully charged when it is stored in the charger.
Note: The charging process is only possible when the tem-
perature of the battery is within the permitted charging tem-
perature range, see section "Technical data".
What the display elements mean
Flashing battery charge indicator (3)
The charging process is indicated by the flash-
ing of the battery charge indicator (3).
Solid light on battery charge indicator (3)
A solid light on the battery charge indicator
(3) signals that the battery is fully charged or
that the temperature of the battery is not
within the permitted charging temperature
range, and can therefore not be charged. The battery is
charged as soon as the allowable charging temperature
range is reached.
When the battery is not inserted, a solid light on the battery
charge indicator (3) signals that the mains plug is inserted in
the plug socket and that the charger is ready for operation.
Errors – causes and corrective measures
Cause
Corrective measures
Battery charge indicator (3) stays lit
Charging not possible
1 609 92A 5YS | (14.10.2020)
AL 1810 CV
min
(240) / 304
min
(288) / 364
4–10
kg
0.17
Cause
Corrective measures
The battery is not connected
Connect battery to charger
(correctly)
correctly
Battery contacts are dirty
Clean the battery contacts;
e.g. by connecting and dis-
connecting the battery sev-
eral times. Replace battery if
necessary
Battery defective
Replace the battery
Battery charge indicator (3)does not light up
Mains plug of the charger is
Insert the mains plug (fully)
not (correctly) plugged in
into the plug socket
Plug socket, mains cable or
Check the mains voltage,
charger defective
have the charger checked if
necessary by an authorised
after-sales service centre for
Bosch power tools
Practical advice
A significantly reduced operating time after charging indic-
ates that the battery has deteriorated and must be replaced.
When the charger is used continuously, or for several con-
secutive charge cycles without interruption, the charger may
heat up. This is, however, harmless and does not indicate
that the charger has a technical defect.
Maintenance and Service
Maintenance and cleaning
In order to avoid safety hazards, if the power supply cord
needs to be replaced, this must be done by Bosch or by an
after-sales service centre that is authorised to repair Bosch
power tools.
After-Sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. You can find explosion drawings and information on
spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the nameplate
of the product.
AL 18V-20
(120) / 154
(144) / 184
4–10
0.21
/ II
/ II
Bosch Power Tools