Operating Indicators; Operating Limits - EAW PROFESSIONAL RS121 User Manual

Hide thumbs Also See for PROFESSIONAL RS121:
Table of Contents

Advertisement

Operating Indicators

Please refer to the chart below to determine the current operating status based on the three LED indicators
located on the rear-input panel of your RS unit.
Indication
LED
Status LED
Signal LED
Limiter LED
ALL LEDs
Limit
The limiting parameters set in RS Products are engineered to provide a high level of protection for the drivers
while maximizing sonic performance and output. The Limit indicator in the rear input panel illuminates when
limiting is occurring. If this is flashing occasionally, meaning no more than once every 3 seconds or so, then
levels are probably OK, but at maximum if this indicator is flashing more than once every 3 seconds or so,
reduce the input signal level.
CAUTION: Electronic limiters cannot provide absolute protection against driver failure. Thus, if limiting is occurring,
it is a warning that excessive signal levels are being approached. EAW is not responsible for damaged or broken
speaker components due to user error.

Operating Limits

The RS products have a Limiter indicator. The speaker is designed to maximize performance and clarity at
limit – if the limit light is blinking every few seconds, no action is needed. If the limit light is flashing more
frequently, or is continuously on, reduce the volume to avoid distortion.
Condition
Color/Repeat
Period
All
components
Green - Solid
working
properly
An input
Green -
signal is being
Flashing/Solid
received by
the amplifier.
The speaker is
Red - Flashing
soft limiting.
The speaker is
Red - Solid
clipping.
Flashing
System Fault
Next Steps
None
None
None
Reduce volume until
the limit light only
flashes occasionally.
Contact EAW
Support.