RS Application Configurations

Rotating the horn

RS products feature a user-rotatable horn, providing exceptional application flexibility and the ability to
maintain the 90
x 60
o
please follow the steps outlined below.
1. Remove the retaining screws securing the grill in place using a standard Philips head screwdriver.
2. Remove the HF horn assembly by unscrewing their retaining screws using standard Philips head
screwdriver.
3. Carefully lift the HF horn/driver assembly from the baffle
4. Rotate the HF horn/driver assembly 90 degrees. *
5. Replace the HF horn/driver assembly back into the enclosure and
re-fasten the retaining screws
6. Replace the grille and re-fasten the retaining screws.
The horn diagram on the left denotes the horn in its original 90° x 60° (HxV) coverage pattern, whereas the horn diagram on the right denotes
The horn orientation can be determined by the labelling of the horn edge. The horizontal writing
denotes the corresponding horizontal dispersion angle, and the vertical writing denotes the
corresponding vertical dispersion angle. The orientation of the horn can also be determined by the
18
coverage pattern when the speaker is mounted horizontally. To rotate the horn,
o
the horn in its 60° x 90° (HxV) coverage pattern.