Description - Hardi MASTER TWIN STREAM Instruction Book

Table of Contents

Advertisement

Description and r
Description and r
Description and r
Description and r
Description and re e e e e vie
MASTER spr
MASTER spr
MASTER spr
MASTER spr
MASTER spra a a a a y y y y y er
er er
er er
F
B
G
E
T T T T T ank
ank
ank
ank
ank
The tank (A), made of impact-proof and chemical
resistant polyethylene, has a purposeful design with no
sharp corners for easy cleaning. Nominal contents: 800,
1000 or 1200 litres.
A large, easy to read tank contents indicator (B) is
placed in front of the tank.
The filling hole (C) and a footboard (D) is placed at the
right hand side of the sprayer. This ensures an easy
access for the filling of sprays, cleaning of the tank, etc.
Rinsing tank(s) (E) are optional equipment.
Clean water tank (F) is optional equipment.
HARDI-FILLER (G) is optional equipment.
F F F F F r r r r r ame
ame
ame
ame
ame
Very strong and compact frame which also has a strong
chemical and weather resistant electrostatic lacquer
coat. Screws, nuts, etc. have been DELTA-MAGNI
treated to be resistant to corrosion.
Pump
Pump
Pump
Pump
Pump
Diaphragm pump model 1302 or 363. The design of the
diaphragm pump is simple, with easily accessible
diaphragms and valves which ensures liquid does not
contact the vital parts of the pump.

Description

view of
vie
vie
vie
w of
w of
w of the
w of
the
the
the
the
C
A
E
D
MANIFOLD sy
MANIFOLD system
MANIFOLD sy
MANIFOLD sy
MANIFOLD sy
The functions of the spray circuits are operated via the
centrally situated MANIFOLD valves with colour coded
plates and pictorial symbols for easy operation (H).
T102-0015
Oper
Oper
Oper
Oper
Opera a a a a ting unit
ting unit
ting unit
ting unit
ting unit
The sprayer is equipped with either a BK operating unit
or an EVC unit (I).
BK operating unit
The BK operating unit consists of; pressure agitator
valve, safety valve, main ON/OFF valve, pressure filter
with pressure gauge, distribution valves with pressure
equalization and HARDI-MATIC pressure control valve.
EVC unit
EVC - Electrical Valve Control. The ON/OFF is linked to
the section valves, which results in a very quick re-
sponse to ON/OFF. The operating unit is constructed of
modules and is electrically controlled via a remote
control box. The unit is fit with built-in HARDI-MATIC.
HARDI-MATIC ensures a constant volume per hectare
of the liquid (l/ha) at varying forward speed within the
same gear when the number of P.T.O. revolutions are
between 300-600 r/min.
GB 04 02 MA
stem
stem
stem
stem
I
H
T102-0016

Advertisement

Table of Contents
loading