Download Print this page

Dakota Digital Odyssey II Series Manual

Advertisement

Quick Links

Wiring:
GND
-
PWR
-
DIM
-
SND
-
Mounting:
The Series II gauge requires a round hole 2-1/16" in diameter. It should be inserted into the opening from the front
and the U-clamp will be installed from the back. Tighten the two nuts on the U-clamp so that the gauge is secure. Gauge
depth to the back of the case is 1". Gauge depth including the mounting studs is 1-7/8".
Factory settings:
Sender type:
Lo warning point:
Hi warning point:
The oil pressure gauge will operate and read correctly between the pressure range of 0-400 psi, 0-150 psi, 0-75 psi, or
0-30 psi depending on the sender type.
This gauge has a user adjustable low and high warning level, which can be set to indicate when the pressure is too low
or too high.
Sender choices:
Gauge Setting Max. Pressure Display Resolution
150
150 psi
400
400 psi
75
73 psi
30
29 psi
These senders have a 1/8" NPT fitting, except for the SEN-03-3 which has 10mm. The engine and sender threads should
be cleaned before installation and no tape or sealant should be used on the threads. The threads are self-sealing. On
single terminal senders, if the sender is mounted away from the engine the sender case must be grounded. On dual
terminal senders either terminal is connected to the gauge GND and the remaining terminal is connected to SND.
Contact Dakota Digital if you need to special order a metric thread sender.
The sender must be a Dakota Digital part SEN-03-1, 03-3, 03-5, 10-1, or 10-2 . Sending units from other
manufacturers will cause incorrect readings. If a sender is not connected properly, the display will show "". If the SND
terminal is shorted to ground, the display will show "---".
ODYR/SLX-03 OIL PRESSURE rev. A
ODYR/SLX-10 FUEL PRESSURE rev. A
ODYR/SLX-19 AIR PRESSURE rev. A
Connect to a main ground location.
Connect to switched 12 VDC power. (An accessory terminal will work for this)
Night Dimming: connect to the head light switch.
Connect to the pressure sender.
SEN-03-1, 150 psi.
10 psi.
100 psi.
1.0
2.0
0.5
0.2
Series II
Sender Part Number
SEN-03-1 or SEN-03-3
SEN-03-5
SEN-10-2
SEN-10-1
MAN# 650003:A

Advertisement

loading

Summary of Contents for Dakota Digital Odyssey II Series

  • Page 1 Contact Dakota Digital if you need to special order a metric thread sender. The sender must be a Dakota Digital part SEN-03-1, 03-3, 03-5, 10-1, or 10-2 . Sending units from other manufacturers will cause incorrect readings. If a sender is not connected properly, the display will show “”. If the SND terminal is shorted to ground, the display will show “---”.
  • Page 2 Setting the warning limits, sender setup, and update speed: The SND terminal is used to enter and change the warning settings. You will need a wire connected to the SND terminal that can be momentarily grounded while you watch the gauge. The headlights should be off or the DIM terminal unhooked so that it does not interfere with the setup.
  • Page 3 Any action for breach of any warranty hereunder, including any implied warranty of merchantability, must be brought within a period of 24 months from date of original purchase. No person or representative is authorized to assume, for Dakota Digital, any liability other than expressed herein in connection with the sale of this product.

This manual is also suitable for:

Odyssey odyr/slx-03 rev. aOdyssey odyr/slx-10 rev. aOdyssey odyr/slx-19 rev. a