The following rules apply for assignment of IP addresses in the system network:
● For all NCUs and/or PCUs/IPCs, the commissioning engineer assigns fixed IP addresses in
the associated address bands, as well as appropriate computer names (host names). All
other operator components are automatically assigned an IP address by the DHCP server.
Its name is generated automatically (for MCP, MPP, HT 8), or is entered at commissioning
(TCU).
● If there are multiple NCUs, IPCs and/or PCUs in the system network, depending on the boot
sequence, the system automatically specifies the DHCP server and automatically ensures
synchronization of all necessary data, so that the next time the system boots any other NCU,
IPC, or PCU could take on the role of DHCP server. However it is better to specify a DHCP
master. This is an NCU, IPC, or PCU in the system network that is available on each system
boot and which regularly takes over the task of the DHCP server and DNS server.
Synchronization of data takes place in any event so that any other NCU, IPC, or PCU can
take over this task, unless you deactivate this option in the DHCP configuration. All non-
master NCUs/IPCs/PCUs wait while the system boots for a preset time for the master to
become available.
Note
In a system network or on a boot server, i.e. on the NCU, IPC, or PCU that accommodates
the active DHCP server, a maximum of 30 operator stations may be operated
simultaneously with the TCU.
A maximum of 10 operator stations with a TCU may connect up simultaneously with the
same HMI application when powering up.
Connection to a company network
Each NCU can be connected via X130, and each PCU/IPC can be connected via "Ethernet 1"
to a company network. The company network is used to exchange operating software with
servers or to execute part-programs directly from servers in the company network. Company
network and system network should always be logically and also physically separated.
Service interface X127
The service interface X127 of the NCU is used for direct connection of a PG/PC for service
purposes. Here, access with STEP 7 to the PLC, and with NCU 7x0.3 PN also to PROFINET
is possible.
With direct connection (peer-to-peer) of a PG/PC to X127 it is absolutely necessary that the PG
is operated as a DHCP client.
Operator panel front: OP 012
Manual, 05/2019, A5E36371591B AB
Networking
5.1 System settings
37