Inserting a FortiGate-5001FA2 board into a chassis

FortiGate-5001FA2 Security System Guide
01-30000-0379-20080606
To change or verify the JP3 jumper setting
To complete this procedure, you need:
A FortiGate-5001FA2 board
A tool for moving jumpers (optional)
An electrostatic discharge (ESD) preventive wrist strap with connection cord
Caution: FortiGate-5001FA2 boards must be protected from static discharge and physical
shock. Only handle or work with FortiGate-5001FA2 boards at a static-free workstation.
Always wear a grounded electrostatic discharge (ESD) preventive wrist strap when
handling FortiGate-5001FA2 boards.
Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal
surface on a chassis or frame.
If you have installed the FortiGate-5001FA2 board in a chassis, remove it.
For removal instructions, see
chassis" on page
17.
Use
Figure 3
to locate the jumper settings on the circuit board.
If required, carefully move the jumper to the correct setting.
You can now insert the board into a chassis and verify that it is operating correctly.
For inserting instructions, see
chassis" on page
13.
The following procedure describes how to correctly use the FortiGate-5001FA2
mounting components shown in
a FortiGate-5000 series chassis slot.
The FortiGate-5001FA2 board left handle contacts to a hidden power switch. The
board must be fully installed in a chassis slot and this handle must be closed and
locked for the FortiGate-5001FA2 board to receive power and operate normally. If
the FortiGate-5001FA2 board is not receiving power, the IPM LED glows blue and
all other LEDs remain off.
It is important to carefully seat the FortiGate-5001FA2 board all the way into the
chassis, to not use too much force on the handles, and to make sure that the
handles are properly locked and engaged with the hidden power switch. Only then
will the FortiGate-5001FA2 board power-on and start up correctly.
Inserting a FortiGate-5001FA2 board into a chassis
"Removing a FortiGate-5001FA2 board from a
"Inserting a FortiGate-5001FA2 board into a
Figure 4
to insert a FortiGate-5001FA2 board into
13