Mira Platinum Dual Installation Manual page 36

Hide thumbs Also See for Platinum Dual:
Table of Contents

Advertisement

Fit the olive and compression nipple
over the outlet pipe and tighten the
compression nipple.
Fit the concealing shroud onto the
shower arm.
Fit the compression nut and olive onto
the shower arm.
Fit the shower arm into the compression
nipple and tighten the compression
nut.
Hand tighten the concealing shroud
onto the backplate.
Do not fit deluge head until after
pipework has been fully flushed through.
Refer to section "Commissioning" in
the Dual Outlet Installation Guide.
Screw the deluge head onto the
shower arm by hand.
Note! Use a suitably sized wrench to
fully tighten (approximately 1/4 turn).
Caution! The shower arm is not
designed to take weight, therefore care
needs to be taken when installing the
deluge head.
1199702-W2-G
Olive
Concealing
Shroud
Flow Regulator
(some models)
36
Backplate
Compression Nipple
Olive
Compression
Nut
Shower
Arm
Shower Arm
Deluge Head