Centralise the brazed pipe in the hole
then screw the ceiling mount plate to
the wooden support.
Offer the deluge head to the brazed
pipe and determine the showering
height required. Push / pull the brazed
pipe using a twisting motion to adjust
the height. Check the height is correct
and use a 15 mm pipe cutter to cut the
pipe to the desired length. Note! Cut
the brazed pipe at least 30 mm above
the ceiling mount plate to allow room
to fit the olive, nut and elbow.
Secure the brazed pipe to the ceiling
mount plate with the olive and 1/2"
BSP nut. Note! This is not a water
tight connection, tighten sufficiently
to clamp the pipe in place.
Offer the Chrome Extension Tube to
the brazed pipe and determine the
length required to allow the tube to
conceal the brazed pipe and protrude
into the ceiling space a minimum of 15
mm. Use a pipe cutter to cut the tube to
the desired length. Remove all burrs.
Note! Take care not to crush the pipe
when cutting.
1199702-W2-G
Chrome
Extension
Tube
28
75 mm
Determine
the showering
height
1/2" BSP Nut
Olive
Brazed
Pipe
Minimum
15 mm