Panasonic WH-SDC03H3E5 Service Manual page 29

Air-to-water heatpump
Hide thumbs Also See for WH-SDC03H3E5:
Table of Contents

Advertisement

M
e
u n
e D
a f
t l u
e S
i t t
g n
e S
i t t
Control pattern Advanced parallel
Heat
Selection of the tank
• "Heat" implies Buffer Tank and "DHW" implies
Domestic Hot Water Tank.
Control pattern Advanced parallel Heat Yes
• Buffer Tank is activated only after selecting
"Yes".
Set the temperature
-8 °C
threshold to start the
bivalent heat source.
Delay timer to start the
0:30
bivalent heat source
(in hour and minutes).
Set the temperature
-2 °C
threshold to stop the
bivalent heat source.
Delay timer to stop the
0:30
bivalent heat source
(in hour and minutes).
Control pattern Advanced parallel DHW Yes
• DHW Tank is activated only after selecting
"Yes".
Delay timer to start the
0:30
bivalent heat source
(in hour and minutes).