14.14.1.8 Setting Temperature and Fan Speed Shift
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Human
Mode
COOL/DRY
Set
temperature
HEAT
14.14.1.9 Rhythmic Temperature Wave Operation
To further maximize the energy saving during ECONAVI operates at low activity level.
Start condition
The unit is operates in Cool or Dry mode under ECONAVI operation, and
o
Human activity sensor detects low activity level continuously for 60 minutes, and
o
Stop condition
Unit is off, or
o
ECONAVI is off, or
o
Human activity sensor detects high activity level or absent, or
o
Control contents
When all start conditions complied, set temperature will shift accordingly as following:
o
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Human
Mode
COOL/DRY
Set
temperature
HEAT
ECONAVI
Precise control of temperature during low activity to maximise energy saving.
Mode
Set
COOL/DRY
temperature
Low activity
Normal activity
+1°C
Low activity
Normal activity
+1°C
Human
Low activity
High activity
-2 °C
High activity
-2 °C
ECONAVI take advantage of the human nature that
human being takes time to feel the temperature rise
during low activity level; the unit adjusts temperature to
maximise energy saving without sacri cing the comfort.
84
Absent
+2°C
-2 °C
Absent
+2°C
-2 °C