3-5. Mounting Control Box

OR

3-6. Connecting Input Power (T Models)

5
4
3
OR
2
Model
1.5 kVA 110 Volt
1.5 kVA 220 Volt
2.5 kVA 220 Volt
OM-716 Page 10
1
1
Input Conductor
Fuse/Circuit Breaker
Size (AWG)
No. 10
No. 12
No. 10
2
1
Size In Amperes
30
15
30
Push-in slots are provided on rear
of box for wall mounting if desired.
The slots will fit over 1/4 inch hex-
head screws. To mount box, pro-
ceed as follows:
1
Control Box
2
Push-In Slots (Not Shown)
Use slots as template and install
screws at desired locations leaving
1/8 inch stickout.
Push rear slots firmly against screw
heads, and slide box down onto
screws.
Ref. ST-800 156
Operate spot welder from a sepa-
rately fused or circuit breaker pro-
tected circuit, and use correct size
input conductors.
1
Rating Label (Not Visible As
Shown On Spot Welder)
2
Cord
3
Parallel Plug On 110 Volts AC
Models
4
Tandem Plug On 220 Volts
AC Models
Do not cut ground terminal off plug.
5
Grounded Receptacle
Connect
plug
to
matching
grounded receptacle.
Ref. ST-800 156