General Installation - Air or Water Cooled

Plumbing Requirements
All models require connection to cold, potable water. A hand actuated valve within site of the machine is
required. Air cooled models have a single 3/8" FPT inlet water connection.
Water cooled models have the same inlet fitting plus an additional 3/8" FPT condenser inlet water connection.
Water Filters
If connecting to water filtration, filter only the water to the reservoir, not to the condenser. Install a new cartridge
if the filters were used with a prior machine.
All models require drain tubing to be attached to them. Air cooled models have a single ¾" FPT drain fitting in
the back of the cabinet. Water cooled models have the same fitting plus an additional ½" FPT drain fitting in the
back of the cabinet.
Install new tubing when replacing a prior ice machine, as the tubing will have been sized for the old model and
might not be correct for this one.
Note: This NSF listed model has a 1" anti-back flow air gap between the water inlet tube end and the
highest possible reservoir water level, no back flow device is required for the potable water inlet.
Drain Tubing:
Use rigid drain tubes and route them separately – do not Tee into the bin's drain and, if water cooled, do not
Tee the condenser drain into the reservoir or bin drain.
Vent the reservoir drain. A vertical vent at the back of the drain, extended about 8 – 10" will allow the gravity
drain to empty and also keep any surges during draining from discharging water out the vent..
Horizontal runs of drain tubing need a ¼" fall per foot of run for proper draining. Follow all applicable codes.
Electrical
See the spec sheet or User's Manual for Minimum Circuit Ampacity or Maximum Fuse Size ratings.
The machine is not supplied with a power cord, one must either be field installed or the machine hard-wired.
The dataplate on the back of the cabinet details the power requirements, including voltage, phase, minimum
circuit ampacity and maximum fuse size. HACR type circuit breakers may be used in place of fuses. Extension
cords are not permitted. Use of a licensed electrician is recommended.
Electrical connections are made inside the junction box in the back panel of the ice machine.
Follow all applicable local, state and national codes.