Control Button Use (from standby)

Set purge level, 1-5 (1 is minimum, 5 is maximum) or Automatic:
• Hold off button in for 3 seconds. Release.
• Press and release the On button to cycle through and select one of the five purge settings or to use the
Automatic setting.
Recall diagnostic code:
• Hold off button in for 3 seconds. Release.
• Press and release the Harvest button to cycle through each of the last 10 error codes from most recent to
oldest.
Clear diagnostic code:
• Hold Clean and Harvest buttons in for 3 seconds to clear all prior codes. If clean mode begins, push Off.
Reset control:
• Depress and release Off, then depress and release On
Start Test Mode:
• Hold Off button in for 3 seconds. Release.
• Hold Clean button in for 3 seconds. Release.
Lock / Unlock control:
To lock ON
• Hold ON button in for 5 seconds, keep holding then press and release Off twice.
To lock OFF
• Hold ON button and then press OFF button once within 3 seconds, wait 5 seconds then press Off twice and
then release On.
To unlock from Locked ON
• Hold ON button in for 5 seconds, keep holding then press and release Off twice.
To unlock from Locked OFF
• Hold ON button and then press OFF button once within 3 seconds, wait 5 seconds then press Off twice and
then release On.
Empty reservoir:
• Hold Clean button in for 3 seconds. Release. Pump and purge valve will be ON for 30 seconds. Repeat as
needed.Test Mode:
• Depress Off for 3 seconds, release. Then depress Clean for 3 seconds.
• The sump will fill the first 30 seconds of the test. If the sump is full it will overflow into the bin. At 30 seconds
the WIV will shut off and the WP will turn on. You will be able to see and hear the water running over the plates.
After 10 seconds the PV and HGV will turn on. Water will be purging from the machine. After 10 more seconds
the compressor will start. 5 seconds later the HGV will close. The compressor will run for a total of 20 seconds.
After which everything will turn off for 5 seconds. After that time the HGV will open and you'll be able to hear
the hissing as the pressure is equalized. 10 seconds later the fan will turn on (if air cooled and fan control
jumped). After 10 seconds all will be off and the output test will be complete