Temperature Sensors - Scotsman Prodigy C0322 Technical & Service Manual

Prodigy series modular cuber. includes prodigy plus d models
Table of Contents

Advertisement

Temperature Sensors

1. Check controller. If the sensor calibration is completely out of range, the code display will read either 5 or 7.
2. Check with an ohmmeter.
Open control box cover, unplug sensor from J6. Water temperature probe:
Measure the temperature of the water.
Push and release the clean button.
Wait one minute.
Measure the resistance of the water probe (two leads next to the open socket) and compare to the
resistance in the chart for that temperature. Any reading within 1000 ohms is acceptable.
Discharge sensor:
Measure the temperature of the discharge line as close to the sensor as possible.
Measure the resistance of the discharge temperature sensor (two leads farthest away from the open socket
on the harness connector) and compare to the resistance in the chart for that temperature. Any reading
within 1000 ohms is acceptable.
3. Alternate procedure: Remove both water and discharge sensors from their places on the ice machine. Put
both into a container of ice water. Put a thermometer in the water. When the thermometer is at 32 degrees F.,
check the resistance of each sensor. The resistance should be within 1000 ohms of 32649.
Water
Temperature Set
January 2015 Page 55
Discharge
Temperature Set

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents