General Installation - Air Or Water Cooled - Scotsman Prodigy C0322 Technical & Service Manual

Prodigy series modular cuber. includes prodigy plus d models
Table of Contents

Advertisement

General Installation - Air or Water Cooled

Location Limitations:
The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge
very warm air into the room out the back. Space must be allowed at the left side and back for air intake and
discharge. Water cooled models discharge warm water into the building's drain. Space needs to be provided
on both sides and above for service access.
Space Limitations
Note: Although the machine will function, ice capacity of air cooled machines will be significantly
reduced with minimal clearance at the sides, back and top. Some space is recommended for service
and maintenance purposes on all models.
6" of space at the sides and back is required for adequate operation. To get the most capacity, locate the
machine away from heat producing appliances and heating ducts.
22 and 30 inch wide models (up to D series: Airflow is in the left side, out the back (as viewed from the front).
22 and 30 inch D series: Airflow is in the front, out the back
48 inch wide models: Air flow is in the front and left side and out the back.
Environmental Limitations
Air temperature
Water temperature
Water pressure
Power supply – acceptable voltage ranges
115 volt model
208-230 volt model
Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance,
corrections to installations, or situations when the machine is operated in circumstances that exceed the
limitations printed above
Minimum
Maximum
50
F.
100
F.
o
o
40
F.
100
F.
o
o
20 psi
80 psi
Minimum
Maximum
104 volts
126 volts
198 volts
253 volts
January 2015 Page 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents