Panasonic CS-NE9JKE-1 Service Manual page 10

Hide thumbs Also See for CS-NE9JKE-1:
Table of Contents

Advertisement

MODEL
Protection Device
Indoor Operation Range
Outdoor Operation Range
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor
-7/-8°C
5. Specifications are subjected to change without prior notice for further improvement.
INDOOR
OUTDOOR
Maximum
Cooling
Minimum
Maximum
Heating
Minimum
Maximum
+8/10°C
HEAT
Minimum
Maximum
Cooling
Minimum
Maximum
Heating
Minimum
Maximum
+8/10°C
HEAT
Minimum
CS-NE12JKE-1, CS-XE12JKE-6
CU-NE12JKE-1
Electronic Control
Dry Bulb
32
16
30
16
10
8
43
-15
24
-15
-15
10
Wet Bulb
23
11
26
18

Hide quick links: