Adjust Dp Motor Speed - Kyocera ECOSYS M6026cdn Service Manual

Hide thumbs Also See for ECOSYS M6026cdn:
Table of Contents

Advertisement

Item No.
U070

Adjust DP Motor Speed

Description
Adjusts the DP original scanning speed.
Purpose
Make the adjustment if the magnification is incorrect in the auxiliary scanning direction when the
DP is used.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original on the DP and press the start key to make a test copy.
4. Press the system menu key.
5. Select [Convey Speed].
Display
Convey
Speed
6. Change the setting value using the cursor left/right keys or numeric keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
Increasing the value makes the image longer, while decreasing the value makes the image
shorter.
7. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Magnification in the auxiliary
scanning direction of CCD
(first side)
Original
Figure 1-3-8
1-3-24
Setting
range
-25 to 25
Copy
Copy
example 2
example 1
2PV/2PW
Initial
Change in
setting
value per step
0
0.1 %