Connector
Pin
YC5
1
GND
Connected to
2
EECLK
drum PWB Y
3
ERASEYDR
4
EEDATA
5
N.C.
6
+3.3V2
7
DA0
8
DA1
YC6
1
GND
Connected to
2
TNSENK
developing
3
+3.3V2
PWB K
4
DLPTHERM
YC7
1
GND
Connected to
2
TNSENM
developing
3
+3.3V2
PWB M
4
N.C.
YC10
1
GND
Connected to
2
TNSENC
developing
3
+3.3V2
PWB C
4
N.C.
YC13
1
GND
Connected to
2
TNSENY
developing
3
+3.3V2
PWB Y
4
N.C.
Signal
I/O
-
-
O
0/3.3 V DC (pulse) EEPROM clock signal
O
0/24 V DC
I/O
0/3.3 V DC (pulse) EEPROM data signal
-
-
O
3.3 V DC
-
-
-
-
-
-
I
Analog
O
3.3 V DC
I
Analog
-
-
I
Analog
O
3.3 V DC
-
-
-
-
I
Analog
O
3.3 V DC
-
-
-
-
I
Analog
O
3.3 V DC
-
-
Voltage
Ground
CL-Y: On/Off
Not used
3.3 V DC power to DRPWB-Y
Ground
Ground
Ground
TS-K detection voltage
3.3 V DC power to DEVPWB-K
DEVTH detection voltage
Ground
TS-M detection voltage
3.3 V DC power to DEVPWB-M
Not used
Ground
TS-C detection voltage
3.3 V DC power to DEVPWB-C
Not used
Ground
TS-Y detection voltage
3.3 V DC power to DEVPWB-Y
Not used