(2) Detaching and refitting the power source PWB

Procedure
1. Remove the right rear cover, right cover
and right lower cover (see page 1-5-6).
2. Remove four screws and then remove
the power source shield.
Screws A and B are unidentical, there-
fore, do not mix up.
3. Remove all connectors from power
source PWB.
4. Remove two screws.
5. Release three hooks and then remove
the power source PWB.
6. Check or replace the power source
PWB and refit all the removed parts.
Screw A
Figure 1-5-41
Hook
YC103 YC105
YC104
Screw
Figure 1-5-42
1-5-29
2PV/2PW-1
Screws A
Screw B
Power source shield
Hook
Hook
YC101
YC102
Screw
Power source PWB