WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Install the pump a minimum of five (5) feet from the inside wall of the pool and spa. Canadian
installations require a minimum of three (3) meters from pool water.
A No. 8 AWG or larger conductor must be wired to the motor bonding lug.
This pump is for use with permanently installed pools and may also be used with hot tubs and
spas if so marked. Do not use with storable pools. A permanently installed pool is constructed
in or on the ground or in a building such that it cannot be readily disassembled for storage. A
storable pool is constructed so that it may be readily disassembled for storage and reassembled
to its original integrity and has a maximum dimension of 18 feet (5.49m) and a maximum wall
height of 42 inches (1.07m).
For hot tubs and spa pumps, do not install within an outer enclosure or beneath the skirt of a hot
tub or spa unless so marked.
IntelliFlo VS+ SVRS is capable of generating systems pressures up to 50 psi. Installers must
ensure that all system components are rated to withstand at least 50 psi. Over pressurizing the
system can result in catastrophic component failure or property damage.
Two Speed Pump Controls Notice (Title 20 Compliance)
Please read the following important Safety Instructions (See page 6 for pump speed setup). When
using two-speed pumps manufactured on or after January 1, 2008, the pump's default circulation
speed MUST be set to the LOWEST SPEED, with a high speed override capability being for a
temporary period not to exceed one normal cycle, or two hours, whichever is less.