Winterizing; Priming The Pump After Service - Pentair IntelliFlo VS+ SVRS Installation And User Manual

Variable speed programmable pump with safety vacuum release system (svrs) protection
Table of Contents

Advertisement

Winterizing

To protect the IntelliFlo VS pump electronics from damage due to freezing conditions, the pump will switch
it self on to generate internal heat when the air temperature drops below 40° F. The IntelliFlo VS "Anti
Freeze" feature is not intended to protect the system plumbing from freezing.
feature is adjustable and can be changed from
information.
1. If the air temperature drops below 40° F the water in the pump can freeze and cause damage.
Freeze damage is not warrantable.
2. To prevent freeze damage follow the procedures listed below.
Shut off electrical power for the pump at the circuit breaker.
Drain the water out of the pump by removing the two thumb-twist drain plugs located at the bottom of
the volute. Store the plugs in the pump basket.
Cover the motor to protect it from severe rain, snow and ice.
Do not wrap the motor in plastic. It will cause condensation and rust on the inside of the motor.
Note: In mild climate areas, when temporary freezing conditions may occur, run your filtering equipment
all night to prevent freezing.

Priming the pump after service

Before a system start-up, the pump and system must be manually primed. Make sure to reopen valves
before operating. To prime IntelliFlo VS, the strainer pot must be filled with water.
CAUTION —
For instructions about how to prime the IntelliFlo VS pump, refer to "Priming the pump for the first time or
after servicing," on page 22.
DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and
the pump will start leaking. If this occurs, the damaged seal must be replaced. ALWAYS
maintain proper water level in your pool. Continued operation in this manner could cause
a loss of pressure, resulting in damage to the pump case, impeller and seal.
40° F
-
50°
F
(4.4° C
-
10°
IntelliFlo VS+ SVRS Installation and User's Guide
The Anti Freeze temperature
C). See page 11 for more
33

Advertisement

Table of Contents
loading

Table of Contents