Intelliflo Vs+ Svrs Menus - Pentair IntelliFlo VS+ SVRS Installation And User Manual

Variable speed programmable pump with safety vacuum release system (svrs) protection
Table of Contents

Advertisement

IntelliFlo VS+ SVRS Menus

MAIN SCREEN
SETTINGS
(page 10)
SPEED 1-8
(page 12)
EXT CONTROL
(page 17)
FEATURES
(page 17)
PRIMING
(page 19)
ANTI FREEZE
(page 21)
Press MENU button to access menus
Pump Address
(1-16) Default: ADDRESS 1
Set Time
(hr:mm) Default: 12:00 AM
AM/PM
Set AM/PM
24 hr.
Temperature Unit
Fahrenheit - Default: F˚
C˚ Celsius
Screen Contrast
(1-5) Default 3
English - Default: English
Language
Set Min Speed
(1100 RPM - 1700 RPM) - Default: 1100 RPM
Set Max Speed
(1900 RPM - 3450 RPM) - Default: 3450 RPM
SVRS Auto Restart
Disabled/Enabled - Default: Enabled
SVRS Restart Time (30 sec. - 5 mins.) Default 2 minutes
PASSWORD
Disabled/Enabled - Default: Disabled
Enter Password (xxxx) Default: 1234
RAMP SPEED
Manual
Speed 1 (1-4)
Schedule
Egg Timer
Speed 5 (5-8)
Schedule
Speed - Default: 1100 RPM
Program 1
Speed - Default: 1500 RPM
Program 2
Speed - Default: 2350 RPM
Program 3
Program 4
Speed - Default: 3110 RPM
Time Out
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
Set Speed (1100 -3450 RPM) Default: 3450 RPM
Quick Clean
Time (1 min. to 10 hrs.) Default: 10 minutes
Default: Enabled
DISABLED/ENABLED
(1 min. to 30 min. hrs.) Default: 11 minutes
MAX PRIMING TIME
(1 - 100%) Default: 1
PRIMED SENSITIVITY
(1 second - 10 minutes) Default: 20 seconds
PRIMING DELAY
Disabled / Enabled - Default: Enabled
DISABLED/ENABLED
SET SPEED
40˚ F - 50˚ F (4.4˚ C - 10˚ C) Default: 40˚ F (4.4˚ C)
PUMP TEMPERATURE
Password Time Out (1 min. - 6 hours) Default:10 minutes
(5 RPM - 400 RPM) Defualt: 200 RPM
Set Speed - Default: MANUAL
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
Disabled
Default: Disabled
Set Speed
Set Start Time
Set Stop Time
Set Speed (1100 RPM - 3450 RPM) Default 1100 RPM
IntelliFlo VS+ SVRS Installation and User's Guide
9

Advertisement

Table of Contents
loading

Table of Contents