20
Priming
(Continued)
4. Press the Select button. The factory default is set to priming "Enabled".
5. To disable priming, press the Select button.
6. Use the Up arrow button. "Disabled" is displayed.
7. Press the Enter button.
8. Press the Down Arrow button. Screen will read "Max Priming Time". Factory default is set to 11
minutes.
9. Press the Select button to change the setting. The cursor will highlight the minutes column.
10. Use the Up or Down arrow button to change the time from 1 minute to 30 minutes..
11. Press the Enter button to save the setting.
12. Press the Down arrow button. The screen will read "Primed Sensitivity". The default for this setting
being "1".
13. Press the Select button to change the setting. The cursor will highlight the number.
14. Use the up or Down arrow button to change the time from 1% to 100%. Increasing the number
makes the Priming less sensitive.
15. Press Enter to save.
16. Press the Down arrow button. Screen will read "Priming Delay". The default for this setting is
20 seconds.
17. Press the Select button to change the Setting.
18. Use the Up or Down arrow button to change the setting from 1 second to 10 minutes. Caution:
Increasing the Priming Delay causes the pump to stay in the priming mode longer thus increasing the
amount of time the pump operates with the SVRS off.
19. Press the Enter button to save the setting. Note: To cancel a change, press the Escape button
instead of the Enter button to exit without saving.
20. Press the Escape button to exit.
IntelliFlo VS+ SVRS Installation and User's Guide