Key lockout
Entering Password
When Password Protection is enabled the press of any button other than the speed button will cause
the Screen to ask for a Password.
To enter password use the left and right arrows to move the cursor and the Up and Down arrow
button to scroll through the digit, then press the Enter button to confirm.

Settings: Ramp Speed

The Ramp Speed can be set from 5 RPM to 400 RPM. The default setting is 200 RPM. This means when
the pump changes speeds it will ramp at 200 RPM increments. For example, when the pump changes speeds
from 1500 RPM to 2350 RPM it will ramp to 1700 RPM wait approximately 5 seconds then move to 1900
RPM, wait 5 seconds and then move to 2300 RPM wait five (5) seconds then move to 2350 RPM. This
adjustment is made available to the user to help minimize the occurrence of a false tripping SVRS alarm when
switching speeds. Note: Using the five (5) RPM setting would cause the pump to take a long time to
switch between speeds. Using the 400 RPM setting may cause false tripping of the SVRS function when
switching speeds.
To access the Ramp Speed menu:
1. Check that the green power LED is on.
2. Press the Menu button. "Settings" is displayed.
3. Press the Select button. "Pump Address" is displayed.
4. Use the Up or Down arrow button to scroll to "Ramp Speed".
5. Press the Select button. The Default setting is 200 RPM.
6. Press the Left or Right arrow button to move cursor and press up and down arrow to change the
setting.
7. Press Enter to save the setting.
FILTER
icon
1100 RPM
POWER
Actual Speed
Running Speed 1
®
12:15
SVRS
15.W
15.W
150 WATTS
RUNNING
IntelliFlo VS+ SVRS Installation and User's Guide
15