Pump Operating Modes

The IntelliFlo VS+ pump can be programmed three ways:
1. Manual Operation: Speed buttons 1-4 can be programmed for Manual operation. This means the
speed button is pressed and then the start button and the pump runs a programmed speed. Speeds
5-8 can not be programmed for Manual operation because there are no buttons associated with
them.
To operate the pump in Manual Mode, press one of the four speed buttons, and press the Start/Stop
button to run the assigned speed for that button. When the pump is running a Manual Speed Setting
(speed 1, 2, 3 or 4 button pressed manually) and a scheduled speed is set to run, the scheduled
speed will take priority regardless of speed number of RPM. When the Scheduled Speed's time is
over, it will not revert back to the manually pressed speed. If the pump is running a schedule and a
speed button is pressed manually, the pump will run the manually selected speed until the next
scheduled speed program.
2. Egg Timer (Duration): Speeds 1-4 can be programmed to run for a duration of time once pressed.
This means that the Speed button is pressed and then the start button and the pump runs a
programmed speed and the speed will turn off at the end of a preprogrammed amount of time.
Speeds 5-8 have no direct pump speed buttons and therefore cannot be programmed with an Egg-
Timer.
3. Schedule: The speed button can be programmed to turn on and off at a certain time. The LED
above the Start/Stop button must be lit for the pump to run schedules. When a speed is set to run in
Schedule mode it can still be operated manually. When a speed is programmed to run 23 hours and
59 minutes per day it will not turn off. For example, for the pump to run 24 hours per day, program
the pump to start at 8:00 AM and stop at 7:59 AM.

Programming the Pump

When the pump is running a manual speed and password time out is activated the pump can be turned off but it
cannot be turned back on. Pressing the Start/Stop button places it in the Running Schedule mode. Therefore, it
will only run Speeds that are Scheduled to come on at their scheduled Start Time.